background image

 

Version 

Document Title 

Release Date 

10 

Enapter Water Tank Module 2.0 

2021-03-18 

 

Enapter Water Tank Module 2.0 

 Rev.10 

 March 2021 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Tank Module 2.0 Manual 

 

Water Tank Module 2.0 

For Enapter Systems  

 

Installation Manual

 

Rev. 2 

 DECEMBER 2018

 

Summary of Contents for Water Tank Module 2.0

Page 1: ...tle Release Date 10 Enapter Water Tank Module 2 0 2021 03 18 Enapter Water Tank Module 2 0 Rev 10 March 2021 Water Tank Module 2 0 Manual Water Tank Module 2 0 For Enapter Systems Installation Manual...

Page 2: ...56 G 56040 Crespina PI Italy VAT no 13404981006 All rights reserved No parts of this manual may be reproduced stored in a data retrieval system or transmitted by any means without the issuer s prior...

Page 3: ...nings and Hazards 6 General safety instructions 7 Hazards description 8 Mechanical Hazards 8 Electrical hazards 9 Environmental hazards 9 TECHNICAL SPECIFICATIONS 10 WATER TANK MODULE 2 0 OVERVIEW 11...

Page 4: ...s rear side Enapter Srl Headquarters Via di Lavoria 56 G 56040 Crespina PI Italy T 39 050 644 281 F 39 050 644 251 Email www enapter com Scope of the document This installation Manual provides the ins...

Page 5: ...ions provided in this manual the unit must only be operated for this purpose Observance of this Installation Manual is part of normal use Danger of injury due to improper use Improper use of the produ...

Page 6: ...s are used in this manual to indicate essential text passages which must be given particular attention Warns of dangers of fatal serious injury Warns of danger of injury Warns of physical damage to th...

Page 7: ...g Keep the electric line away from heat oil and sharp edges 6 Use always personal protection devices wear protective goggles Wear ear muffs or plugs in noisy areas Wear gloves when handling parts with...

Page 8: ...forming any operation the operators must wear the appropriate PPE such as cut resistant gloves safety shoes protective goggles etc No special training is needed to perform the preliminary steps of the...

Page 9: ...puts Do not reverse the polarity of inputs and outputs Equip the power supply line with proper protections Do not short circuit the cables of the cabinet Do not insert any mechanical parts primarily m...

Page 10: ...Dimensions Width 483mm Depth 640mm Height 310mm Weight Empty 25 kg Full 60 kg Max outlet water flow rate 3 8 liters per minute Max outlet pressure 4 8 bar Operative Power Consumption 50 W Max power co...

Page 11: ...rom a purification system H2O IN H2O OUT W1 2 High pressure water outlet port towards Electrolysers H2O OUT OVERFILL W1 4 Overfill port only used when the tank is overfilled with water OVERFILL TANK D...

Page 12: ...ctrolyser if it is stable means correct operation 9 Power Power Supplies power to the water tank module Ground Live and Neutral 200 220V AC 50 60Hz 10 The fuse holder is used to hold the fuses inside...

Page 13: ...ine of the tank H2O IN The solenoid valve N C closes when the maximum filling level is reached and opens when the medium level is reached thanks to three separate level switches low medium and high th...

Page 14: ...RS MUST PERFORM THE FOLLOWING ACTIONS INLET H2O IN port Connect the 8mm LLDPE pipe to the H2O IN port This is an inlet port You must connect the source of water you want to store inside the tank at th...

Page 15: ...out only if the high level sensor fails This is a rare condition but please be sure this pipe is connected to the User s drainage system Moreover be sure that at any point the pipe connected to this...

Page 16: ...ed inside the tank to make it easier to move the WTM So 1 Shut down the WTM with the external switch label 12 2 Quick connect the provided 10 mm LLDPE pipe with the white connector to port TANK DRAIN...

Page 17: ...ns using the proper power supply cables 1 5 mm2 is sufficient Brown live blue neutral and yellow green ground Ensure to use the male connector in the correct orientation Power ON When the water connec...

Page 18: ...turns on If the manual valve between WTM and Water Purification System is open the de ionized water enters the tank inside the WTM filling it The green led turns on as soon as the level indicator show...

Page 19: ...ns on as soon as the level indicator shows that the tank is filled for 2 3 This process requires some time it depends on the pressure of the water coming from the source When water is required opening...

Page 20: ...t and there is no problem in the water supply the electrovalve may be in overheating protection Red led The pump is not working correctly check the fuse in the right fuse holder If it is intact you ma...

Reviews: