background image

 

                                             Page 3 of 

3                                   

Ethernet Extension Experts

 

 

 

 

 For wiring over 1,970ft (600m) you must change DIP Switch 3 from 30a (ON) to 17a 
(OFF).   For troubleshooting, first examine the backbone wiring pair and make sure you have 
solid   connections.  The Interlink Link LED will be lit solid Green with rapid pulsing on each 
850 CPE unit to show proper connection and pairing.  If the Interlink Link LED Link is flashing 
slow to fast and never goes solid …. Then follow the steps below: 

    1) Make sure your wiring is straight through and not connected to any Telco punch  
        down block; If so remove from the block and use Telco butt clips to bridge wire. 

 

    2) Check for a firm connection of the RJ-11 connections in each 850 CPE unit and  
 

8950 DSLAM, and power is applied to both the DSLAM and CPE units. 

 
 

     

3) You can easily isolate any issue by performing an out of the box test confirm either the 850 CPE  

                     or your wiring. It is possible an outside interference has been introduced into your wiring. 
 
 

Expected Throughput speeds utilizing CAT5 or better wiring 

 

 
 

Up to 700ft (200m) 

 

 

 

- 100Mbps Full Duplex 

 

700ft (200m) to 1,350ft (400m) 

 

-   95Mbps Full Duplex 

 

1,350ft (400m) to 1,970ft (600m)   

-   75Mbps Full Duplex 

 

1,970ft (600m) to 2,625ft (800m)   

-   55Mbps Full Duplex -17a mode 

 

2,625ft (800m) to 3,280ft (1,000m)  

-   44Mbps Full Duplex -17a mode 

 

3,300ft (1,005m) to 6,000 (1,828m)  

-   30Mbps Full Duplex -17a mode 

 

6,100ft (1,860m) to 8,000 (2,440m)  

-   10Mbps Full Duplex -17a mode 

 

 

Performance Settings

  

 

        A DIP Switch is provided on the left side of each unit for setting line 

 

  

        performance attributes. 

 

     If the Interlink cabling is more than  
    1,500ft / 457m – Set DIP Switch 3 up  
     For 17a mode. This optimizes 
     faster symmetrical throughput at higher  
     distances. 
    
     If the Interlink cabling is less than 1,500ft 
    457m - the DIP switch 3 must be down For 30a mode 
    (set to ON) position for the unit to work properly. 

 
 

 
 

        

 

Default DIP settings 
           850 CPE – All down set in the ON position 
           850 CPE CO   – DIP position 1 up (OFF) 
                                    DIPs 2-4 down (ON) 
 

DIP 1 – CO/CPE mode 

 

 

DIP 2 – Fast/Interleave mode 

 

DIP 3 – 30a/17a mode – short distance or  

 

              long distance mode  

 

DIP 4 –  6dB/9dB –  9dB mode cleans up the 

 

          signal noise ratio on the telephone wiring 