WEL-
200™ Operating Instructions
13
Document no.
10320104 Revision 2.0
3-1-19
When channel assignment mode is entered, the active channel’s LED will turn on for 0.25
seconds, once per cycle.
If the edge resistance is above normal, due to lack of/improper termination or cable
damage, the offending channel’s LED will turn on for 0.25 seconds, 2x per cycle.
If the transmitter batteries fall below their ideal operating voltage , the LED for its assigned
channel will turn on for 0.25 seconds, 3x per cycle.
Pending channel connection
0s
0.25s
0.5s
0.75s
1s
1.25s
1.5s
1.75s
2s
ON
OFF
Edge resistance above normal
0s
0.25s
0.5s
0.75s
1s
1.25s
1.5s
1.75s
2s
ON
OFF
Transmitter battery low
0s
0.25s
0.5s
0.75s
1s
1.25s
1.5s
1.75s
2s
ON
OFF