IRB-HB Instructions 

 

Document no.  10280204   

REV 1.3 

    

 

 

 

Configuration settings  

 

SW4  SW3  SW2  SW1  FUNCTION 

OFF  Configuration 1 - heartbeat output, 300Hz, 0Hz 

ON  Configuration 2 - heartbeat output, 300Hz, 2Hz, 0Hz 

 

 

Green status indicator 

 

IRB-HB-T (transmitter) 

ON 

Power 

IRB-HB-R (receiver) 

Flashing 

Blocked beam or not aligned 

IRB-HB-R (receiver) 

ON 

Aligned 

 

 

SPECIFICATIONS 

     

    

 

Operating range 

up to 115 ft. (35m) 

Detection angle 

24

o

 

Sensitivity adjustment 

potentiometer 

Power indicator 

Green LED  

Detect indicator 

Green LED  

Configuration selection switch 

2 modes, pulsed (3 frequency), pulsed (2 frequency)  

Power protection  

Thermal fuse 

Power Supply 

6…35 VDC 

Current 

15mA (12VDC, includes TX and RX wired in parallel) 

Operating temperature 

-40°F…170°F (-40°…77°C) 

Environmental 

NEMA 4X 

Dimensions (L x W x H) 

 2.3” (57mm) x 2.6” (65mm) x 3.7” (94mm) 

Weight 

TX - 0.35 lbs (159 g), RX 0.35 lbs (159 g)  

Connections 

TX-2 terminal, RX-2 terminal 

 

 

INSTALLATION

 

    

 

Install the IRB-HB according to instructions from the gate operator 

manufacturer. The intent of External Entrapment Protection Device Type 

B1 non-contact sensor is to protect a person from being accidentally 

injured by the moving gate or door.  

 

 

 

1.  Disconnect the IRB-HB from power before installing or servicing the device. 

 

2.  Always follow the instructions of the gate operator manufacturer regarding installation of 

type B1 sensors on the gate operator. The instructions of the gate operator manufacturer 

always supersede any instructions given in this or any other instructions by EMX Industries 

Inc. 

 

3.  Connect the IRB-HB power supply per requirements indicated in the specification table. 

 