background image

 
WEL-

200™ Operating Instructions 

 

Document no.

  10320104                                            Revision 2.0 

3-1-18

 

 

CABLE GRIP INSTALLATION for both transmitter and receiver 

The cable grip provides a NEMA 4X rating.  To maintain a watertight seal follow these instructions: 

a.

 

Cable must be 0.181 – 0.312 (4.6 – 7.9mm) diameter for proper seal using the cable grip 
insert as supplied.  A separate white insert is provided when using cables sizes 0.069 – 
0.187  (1.8 -4.7mm).  To maintain a watertight seal, use only round cables, do not use 
individual wires or any cable that is not round.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.    

Remove sealing nut. 

 
2.     Remove dark insert from body (compression fingers) and replace with white insert. 
 
3.     Hand-tighten the sealing nut to secure. 
 

a.

 

Hand-tighten the sealing nut as far as possible.  Hold the body hex stationary with a 
wrench. Using a second wrench, tighten the sealing nut to 40 in. lbs. until the cable is 
securely held in place. 

 

b.

 

If the cable has different diameter point the cable ingress down to prevent water 
penetration.

 

 

 

 

 

 

 

Summary of Contents for WEL-200 Series

Page 1: ...44128 P 800 426 9912 F 216 518 9884 Sales Inquiries salessupport emxinc com Technical Support technical emxinc com www emxinc com WEL 200 W I R E L E S S E D G E L I N K TM O P E R A T I N G I N S T R...

Page 2: ...ons 1 Document no 10320104 Revision 2 0 3 1 18 Cautions and Warnings Contents2 Specifications 3 Product Overview 4 Controls and Indicators 5 Connections 7 Installation and Operation 8 Troubleshooting...

Page 3: ...ollowing two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation UL File E3157...

Page 4: ...y Form C contacts NO COM NC OPEN direction 300Hz pulsed Open collector transistor output opto isolated CLOSE direction 300Hz pulsed Open collector transistor output opto isolated NA Resistive terminat...

Page 5: ...suring compliance with 2018 UL325 monitoring standards Each transmitter can run for up to two years on two AA lithium batteries The receiver connects with up to four transmitters with separate relay a...

Page 6: ...n assignment switch Assigns channel to either open or close direction output function 6 Power indicator On constantly when receiver is powered up 7 Status indicator Shows current system status 8 Close...

Page 7: ...or the best performance and longest life Observe polarity indication on the battery holder 2 Transmitter status LED Blinks twice every two seconds if not connected once if connected Blinks once every...

Page 8: ...rection 4 PLS CLOSE OUT Pulsed output for CLOSE direction 300 0 Hz 5 RELAY OPEN NC Normally closed connection for OPEN direction 6 RELAY OPEN COM Common connection for OPEN direction 7 RELAY OPEN NO N...

Page 9: ...hannel to either OPEN or CLOSE direction relay function depending on the location of each edge 4 For 10K resistive monitoring place the jumper in the 10K position for both OPEN and CLOSE direction rel...

Page 10: ...cables sizes 0 069 0 187 1 8 4 7mm To maintain a watertight seal use only round cables do not use individual wires or any cable that is not round 1 Remove sealing nut 2 Remove dark insert from body co...

Page 11: ...atus LED will flash on off once every 2 seconds 2 2 Set channel to the desired OPEN CLOSE direction function using the MODE dip switch 2 3 Install 2 AA Lithium batteries in the WEL 200T transmitter 2...

Page 12: ...behavior double check the edge wiring termination and transmitter batteries Notes 1 If channel 1 and 4 switches are pressed simultaneously during power up the receiver will perform a factory reset an...

Page 13: ...to 12k check wires for damage Relay NO COM connected pulse output 0 Hz LED flashes 2x per cycle 0 25 seconds on 0 25 seconds off Edge resistance above normal improper connection damaged wires Make sur...

Page 14: ...r cable damage the offending channel s LED will turn on for 0 25 seconds 2x per cycle If the transmitter batteries fall below their ideal operating voltage the LED for its assigned channel will turn o...

Page 15: ...WEL 200 Operating Instructions 14 Document no 10320104 Revision 2 0 3 1 18 Transmitter is inactive ON OFF 0s 0 25s 0 5s 0 75s 1s 1 25s 1 5s 1 75s 2s Dimensional Outline Receiver...

Page 16: ...WEL 200 Operating Instructions 15 Document no 10320104 Revision 2 0 3 1 18 Dimensional Outline Transmitter...

Page 17: ...misuse overloading altered products damage caused by incorrect connections lightning damage or use other than intended design There is no warranty of merchantability There are no warranties expressed...

Page 18: ...WEL 200 Operating Instructions 17 Document no 10320104 Revision 2 0 3 1 18 BLANK PAGE...

Page 19: ...WEL 200 Operating Instructions 18 Document no 10320104 Revision 2 0 3 1 18 BLANK PAGE...

Page 20: ...ocument no 10320104 Revision 2 0 3 1 18 4564 Johnston Parkway Cleveland Ohio 44128 United States of America www emxinc com Technical Support 216 834 0761 technical emxinc com Sales 216 518 9888 Fax 21...

Reviews: