background image

EMX Industries, Inc. 

Tech support: 216-834-0761 

3/3

 

USVD-4X_Rev2.0_081419                                    [email protected]

 

 

 

1.

 

Knock out the PG hole that will be used to pass the wires through.  

2.

 

Pass  the  body  of  the  cable  grip  through  the  
PG hole and tighten the backing to attach the 
cable grip to the housing.   

Cable Grip 

 
 
 

3.

 

Thread all wires through the cable grip and 
into the housing. 

4.

 

Turn  off  the  power  supply  when  connecting 
the  USVD-4X  power  wires  to  the  terminal 
block. The terminals are not polarity sensitive.

 

5.

 

Wire the USVD-4X according to the operator 
instructions and the terminal block table. 

6.

 

Configure the DIP switch to the pulse/presence and delay mode desired. 

7.

 

Mount the USVD-4X perpendicular to the side of the vehicle at the location of desired detection 
and 22-

24” above the height of the pavement surface where the vehicle is located. 

 

 

If using multiple USVD-4Xs it may be necessary to place a barrier up to 24x

24” between the 

sensors to prevent units from interacting.   

8.

 

Adjust  the  sensitivity  by  rotating  the  sensitivity  adjustment  clockwise  to  decrease  and 
counterclockwise to increase (#4 in image on previous page). 

 

 

In most applications it is unnecessary to reduce sensitivity. 

 

 

If using multiple USVD-4Xs, it may be useful to reduce the sensitivity to reduce crosstalk. 

 

 

Two test points to the right of the sensitivity adjustment labeled GND and SENS may be 
used to measure the position of the sensitivity adjustment. 5V is the maximum sensitivity. 

 

Troubleshooting 

 

Symptom 

Cause 

Solution 

Constant detection 

Solid material blocking 
transducer 

Increase  the  angle  of  the 
housing to avoid detection of the 
ground or other low objects. 

 

Turn down the sensitivity by 1V 
by  rotating  the  sensitivity 
adjustment  counterclockwise. 
Attach a multimeter to the GND 
and SENS pins to the right of the 
sensitivity  adjustment  to  read 
the change in voltage.   

 

Warranty 

 

EMX Industries, Inc. products have a warranty against defects in materials and workmanship for a period 
of two years from date of sale to our customer.  

Installation  

TIP:

 

TIP:

 

USVD-4X Housing 

Backing 

Sealing Nut 

Body 