Product Overview 

 

The IRB-325 conforms to the UL325 standard when used with the powder coated steel 
hoods. Registration reference number 9901994.  The IRB-325 photocell is used as an 
external entrapment protection device type B1 non-contact sensor for use with automatic gate 
and door openers. 

 

The IRB-325 transmitter and receiver have a line of site range of up to 65 feet. The IRB-325 
operates on 12 VDC to 24 VAC and draw 150 mA maximum. 

 

The IRB-325 receiver is activated whenever anything interrupts the beam from the 
transmitter, triggering the relay output to change state and send a signal to the operator that 
there has been an interruption. 

 

Technical Specifications 

 

 

 

Controls, Indicators and Connections 

 

 

 

 

Transmitter   

 

 

     Receiver

 

 

 

 

 
 

 

 
 
 

 
 

 
 

 

 
 

 
 

The IRB-325 is an external entrapment device Type B1 non-contact sensor for use 
with automatic gate operators. If the IRB-325 is used as the primary entrapment 
protection device it must be monitored for presence and fault condition. 

 
 

 

Power Supply 

12 Volts Dc to 24Volts AC 

 Power Supply Tolerance 

+/- 20% 

 Current Draw 

150 mA maximum 

 Housing Material 

UL and CSA Type 4, 4X, 3, 3R, 12, 13 rating  and powder coat steel hood 

 Relay Type 

Type C       Rating 1A @ 30 VDC 

 Temperature Range 

-40

o

 F to 170

o

 F 

 Connector  

Screw terminal isolated contact  (2) transmitter  (5) receiver 

 Power Indicator 

Green LED 

 Detect Indicator 

Red LED 

 Dimensions 

H=5.03 in, W=3.06 in, D=3.02 in 

 Range 

6 feet to 65 feet line of sight 

Power 

LED 

 

Green SMT glows when power is applied 

Power 

LED 

 

Green SMT glows when power is applied 

Connections 

Screw terminal 

 

2 position for power source 

Connections 

Screw terminal 

 

5 position for power and controls 

Detect 

LED 

 

(2) Red SMT LEDs glow on detection 

Summary of Contents for IRB-325

Page 1: ...g Instructions This product is an accessory or part of a system Always read and follow the manufacturer s instructions for the equipment you are connecting this product to Comply with all applicable c...

Page 2: ...IRB 325 Instructions 2 Document no REV 1 0 Date 10 25 2007...

Page 3: ...tions Transmitter Receiver The IRB 325 is an external entrapment device Type B1 non contact sensor for use with automatic gate operators If the IRB 325 is used as the primary entrapment protection dev...

Page 4: ...lly closed contact for entrapment protection connect terminals 1 NC and 2 COM to the designated terminals in the gate operator 8 For operators that require normally open contact for entrapment protect...

Page 5: ...e and powered make sure the transmitter TX is in line of sight of the receiver RX 5 Introduce an obstruction in form of a hand between the IRB 325 transmitter and receiver Two Red LED s on the receive...

Page 6: ...ighly reflective surfaces Red detect LED stays on Sensitivity too low Transmitter does not have power Receiver does not see transmitter Move jumpers J1 and J2 to a higher position Check power source f...

Page 7: ...red photocell includes transmitter and receiver Accessories IRB 325 HD Set of 2 powder coated steel protective hoods required for UL 325 IRB 325 PT Mounting post 2 in x 2 in x 2 ft black powder coat I...

Page 8: ...tructions 8 Document no REV 1 0 Date 10 25 2007 4564 Johnston Parkway Cleveland Ohio 44128 United States of America WEB http www emxinc com E mail salessupport emxinc com Telephone 216 518 9888 Fax 21...

Reviews: