6.2
Events
During operation, BMS keeps a log of the most recent events internally. It consists of 128 entries,
each of which stores an event type identifier and occurrence timestamp. Once all 128 entries a filled,
any new event replaces the oldest entry. All event types are described in the Table
6.2
.
Table 6.2: List of events and their descriptions
ID
Event
Description
1
Cells voltage critically high
"Cell Over-Voltage" protection has been activated
2
Critical high voltage recovered
"Cell Over-Voltage" protection has been deactivated
3
Cells voltage critically low
"Cell Under-Voltage" protection has been activated
4
Critical low voltage recovered
"Cell Under-Voltage" protection has been deactivated
5
Charge current critically high
"Charge Over-Current" protection has been activated
6
Charge critical high current recovered
"Charge Over-Current" protection has been deactivated
7
Discharge current critically high
"Discharge Over-Current" protection has been activated
8
Discharge critical high current recovered
"Discharge Over-Current" protection has been deactivated
9
External temperature critically high
"External Over-Temperature" protection has been activated
10
External temperature recovered
"External Over-Temperature" protection has been
deactivated
11
External temperature critically low
"External Under-Temperature" protection has been activated
12
External temperature recovered
"External Under-Temperature" protection has been
deactivated
13
Internal temperature critically high
"Internal Over-Temperature" protection has been activated
14
Internal temperature recovered
"Internal Over-Temperature" protection has been deactivated
15
Internal temperature critically low
"Internal Under-Temperature" protection has been activated
16
Internal temperature recovered
"Internal Under-Temperature" protection has been
deactivated
17
User Connected
"User has connected to the BMS"
18
User Disconnected
"User has disconnected from the BMS"
19
Firmware Updated
BMS firmware has been updated
20
Power up
BMS was powered-up
21
Contactor Emergency Cut-off
Contactor cut-off due to incorrect pre-charging conditions
22
Contactor Soft-start timeout
Contactor pre-charging was taken too long time
23
Charging finished
Charging process has been finished
24
Charging started
Charging process has started
25
Charging error
Charging process has stopped due to an error
26
Cells Count Mismatch
"Cells Count Mismatch" protection has been activated
27
Cells Count Mismatch Recovered
"Cells Count Mismatch" protection has been deactivated
28
Forced protection deactivation
All protections have been cleared manually
27