background image

 

LP11002 Hardware Installation Manual

Page 6

Applying Power

To apply power:

1.

Verify that the HBA is securely installed in the computer.

2.

Verify that the correct media is attached.

3.

Plug in and turn on the computer.

4.

Observe LEDs for Power On Self Test (POST) results.

Viewing the LEDs

Green and yellow LEDs can be seen through openings in the HBA's mounting bracket. Green indicates 
firmware operation and yellow signifies port activity. Each port has a corresponding set of green and 
yellow LEDs.

Figure 4: LEDs

POST Conditions and Results 

POST conditions and results are summarized in the following table:

Table 4: POST Conditions and Results

Yellow LED

Green LED

State

Off

Off

Wake-up failure (Dead board)

On

Off

POST failure (Dead board)

Slow Blink

Off

Wake-up failure monitor

Fast Blink

Off

POST failure

Flashing

Off

POST processing in progress

Off

On

Failure while functioning

On

On

Failure while functioning

1 Blink

On

1Gb Link rate -Normal, link up

2 Blinks

On

2Gb Link rate -Normal, link up

3 Blinks

On

4Gb Link rate -Normal, link up

Off

Slow Blink

Normal -link down or not started

Slow Blink

Slow Blink

Off-line for download

Fast Blink

Slow Blink

Restricted off-line mode (Waiting for restart)

Flashing

Slow Blink

Restricted off-line mode (Test active)

Summary of Contents for LP11002

Page 1: ...LP11002 HBA Installation Manual...

Page 2: ...rd FibreSpy HBAnyware InSpeed MultiPulse SLI and SBOD are trademarks of Emulex Corporation All other brand or product names referenced herein are trademarks or registered trademarks of their respectiv...

Page 3: ...ures 1 Compatibility 2 Prerequisites 2 Setting the Jumpers 3 Installing the Host Bus Adapter 4 Attaching Media 5 Applying Power 6 Viewing the LEDs 6 POST Conditions and Results 6 References 7 Specific...

Page 4: ...roughput achieved via full duplex hardware support End to end data path parity and cyclical redundancy check CRC protection including internal data path random access memory RAM Architectural support...

Page 5: ...nion Directive of Restriction of Hazardous Substances RoHS Compatibility Prerequisites PCI 32 64 bit data and 33 66 MHz clock frequency 3 3 V signaling PCI X Mode 1 64 bit data and 66 100 133 MHz cloc...

Page 6: ...in electronic components that can be damaged by static electricity through an electrostatic discharge ESD event To prevent ESD damage maintain constant contact with any grounded metal surface A ground...

Page 7: ...bracket and store it for future use 7 Align the new mounting bracket tabs with the holes in the HBA 8 Replace the screws that attach the HBA to the bracket 9 Insert the HBA into the empty 32 or 64 bi...

Page 8: ...to the HBA you are ready to apply power to the computer Note The HBA will not allow normal data transmission on an optical link unless it is connected to another similar or compatible laser product th...

Page 9: ...s and Results POST conditions and results are summarized in the following table Table 4 POST Conditions and Results Yellow LED Green LED State Off Off Wake up failure Dead board On Off POST failure De...

Page 10: ...ode 1 100 133 MHz host 1 5 watts typical 3 3 VDC 4 1 watts typical 5 0 VDC 6 0 watts total typical In a PCI X Mode 2 133 MHz host 1 5 watts typical 3 3 VDC 4 3 watts typical 5 0 VDC 6 5 watts total ty...

Page 11: ...wn expense The reader is cautioned that changes or modifications made to the equipment not expressly approved by Emulex could void the user s authority to operate this equipment The above statement ap...

Page 12: ...e that this equipment has been approved for business purposes with regards to electromagnetic interference If purchased in error for use in a residential area you may wish to exchange the equipment wh...

Page 13: ...LP11002 Hardware Installation Manual Page 10...

Page 14: ...regulation 21 CFR subchapter J The certification is indicated by a label located on the optical small form factor transceiver In Europe all optical small form factor transceivers sold by Emulex are c...

Page 15: ...in the U S by the DHHS and within Europe by EN60825 1 EN60825 2 Short wavelength and long wavelength small form factor transceivers allow normal data transmission on the optical link when they are co...

Page 16: ...al Page 13 factor transceiver and the system level documentation and labeling Copies of the certificate of conformity for any small form factor transceiver sold by Emulex can be obtained upon request...

Reviews: