background image

 

LP11000 Hardware Installation Manual

Page 3

Setting the Jumpers

The device ID jumpers are used in custom applications. Do not change the jumper settings for a 
standard Emulex installation.

The HBA has one six-post jumper block that controls the HBA's device ID. The ID is selected by 
installing a jumper between posts 1 and 2, or 3 and 4, or 5 and 6. If no jumper is installed, the host bus 
adapter reports a device ID of 1AE5.  

Figure 1: The LP11000 HBA Jumper Settings

Caution: Emulex LightPulse® HBAs contain electronic components that can be damaged by static 

electricity through an electrostatic discharge (ESD) event. To prevent ESD damage, maintain 
constant contact with any grounded metal surface. A grounding wrist strap is useful for this 
purpose. Handle the card carefully at all times and preferably by the edges. Avoid touching 
electronic components and keep the card in the original packaging until you are ready for 
installation.

Table 2: Jumper Settings (Port 0)

PCI Identifier

P0_JX

FD00

1–2

FD01

3–4

1AE5*

5–6

Note: * Without a jumper, the HBA reports a device ID of 1AE5.  Most software drivers 

require a PCI device ID of FD00 to properly identify and control the HBA.  Do not 
attempt to operate the HBA  with the PCI device ID set to 1AE5 unless recommended 
by the driver installation instructions.

Summary of Contents for LP11000

Page 1: ...LP11000 HBA Installation Manual...

Page 2: ...rd FibreSpy HBAnyware InSpeed MultiPulse SLI and SBOD are trademarks of Emulex Corporation All other brand or product names referenced herein are trademarks or registered trademarks of their respectiv...

Page 3: ...ures 1 Compatibility 2 Prerequisites 2 Setting the Jumpers 3 Installing the Host Bus Adapter 4 Attaching Media 5 Applying Power 6 Viewing the LEDs 6 POST Conditions and Results 6 References 7 Specific...

Page 4: ...via full duplex hardware support End to end data path parity and cyclical redundancy check CRC protection including internal data path random access memory RAM Architectural support for multiple uppe...

Page 5: ...opean Union Directive of Restriction of Hazardous Substances RoHS Compatibility Prerequisites PCI 32 64 bit data and 33 66 MHz clock frequency 3 3 V signaling PCI X Mode 1 64 bit data and 66 100 133 M...

Page 6: ...by static electricity through an electrostatic discharge ESD event To prevent ESD damage maintain constant contact with any grounded metal surface A grounding wrist strap is useful for this purpose Ha...

Page 7: ...e use 7 Align the new mounting bracket tabs with the holes in the HBA 8 Replace the screws that attach the HBA to the bracket 9 Insert the HBA into the empty 32 or 64 bit PCI or PCI X bus slot Press f...

Page 8: ...to the HBA you are ready to apply power to the computer Note The HBA will not allow normal data transmission on an optical link unless it is connected to another similar or compatible laser product th...

Page 9: ...s and Results POST conditions and results are summarized in the following table Table 4 POST Conditions and Results Yellow LED Green LED State Off Off Wake up failure Dead board On Off POST failure De...

Page 10: ...ode 1 100 133 MHz host 1 0 watts typical 3 3 VDC 3 3 watts typical 5 0 VDC 4 7 watts total typical In a PCI X Mode 2 133 MHz host 1 0 watts typical 3 3 VDC 3 6 watts typical 5 0 VDC 5 3 watts total ty...

Page 11: ...expense The reader is cautioned that changes or modifications made to the equipment not expressly approved by Emulex could void the user s authority to operate this equipment The above statement appl...

Page 12: ...e that this equipment has been approved for business purposes with regards to electromagnetic interference If purchased in error for use in a residential area you may wish to exchange the equipment wh...

Page 13: ...LP11000 Hardware Installation Manual Page 10...

Page 14: ...regulation 21 CFR subchapter J The certification is indicated by a label located on the optical small form factor transceiver In Europe all optical small form factor transceivers sold by Emulex are c...

Page 15: ...in the U S by the DHHS and within Europe by EN60825 1 EN60825 2 Short wavelength and long wavelength small form factor transceivers allow normal data transmission on the optical link when they are co...

Page 16: ...al Page 13 factor transceiver and the system level documentation and labeling Copies of the certificate of conformity for any small form factor transceiver sold by Emulex can be obtained upon request...