![EMS iris+ User Manual Download Page 6](http://html.mh-extra.com/html/ems/iris/iris_user-manual_2404741006.webp)
©2018 EMS Ltd. All rights reserved. Page 6 of 12
MK193 Iss6 30/10/2018 AJM
Transmitters
Handpush transmitters: The handpush transmitter is shown below. Its operation when
configured as an opposed action device is shown:
Green push button pressed
Red push button pressed
Both red push buttons pressed together
Local alarm initiated
No effect
Full alarm activation
7500 handpush transmitter
Red button
Red button
Green button
Alarm latch:
If on the pressing of a single Red button the internal red LED lights, this indicates
a Full Alarm has been initiated from the hand push within the last 24 hours.
Battery low indication:
Battery conditions can be viewed on a Local or Full Alarm activation.
If the yellow battery LED is present, the battery voltage in the handpush is low and therefore
require replacement.
After replacing the batteries, it is recommended that the device is tested to ensure the
batteries have been inserted correctly and the device has been returned to a fully operational
condition.