Operating instructions
Keyswitch
TEST
position;
all transmitters or hard wired inputs programmed to the system are able to be
tested. A full alarm / local transmission or hard wired input activation will be acknowledged on
the LCD screen and the buzzer will sound for approximately 1 second. With the unit set to the
factory preset, whilst in this key position none of the relays should be observed to change state
upon receipt of a valid transmission or hard wired input activation.
RESET
position;
all outstanding events will be cleared. Access to the system menus can be
gained by pressing the 0 (zero) key and entering a valid user PIN number. With the unit set to
the factory presets, whilst in this key position none of the relays should be observed to change
state upon receipt of a valid transmission or hard wired input activation.
CLEAR
position;
any alarm transmission(s) will be acknowledged on the LCD screen and the
alarm relay will latch until cleared by moving the keyswitch to reset. A local transmission will be
acknowledged on the screen (providing an alarm transmission has not been received), the
local relay will change state for a period of approximately 4 seconds and the buzzer will then
sound until the keyswitch is moved to the reset position. Use of the
or
buttons allows
the user to step through the events in the incident log.
Display
The 80 character LCD display shows the current state of the system, or displays any activations
not yet cleared to the event log. Information is also provided on the bottom line about the
current time and date. A single alpha numeric digit, preceding the time, displays information
about the receipt of transmissions or warnings of RFI (radio frequency interference) and power
supply failure.