Manufacturer
Carrier Manufacturing Polska Sp. Z o.o. Ul.
Kolejowa 24. 39-100 Ropczyce, Poland
Year of manufacture
See devices serial number label
Certification
Certification body
CPR DoP
0359-CPR-00436
Approved to
EN54-18:2005. Fire detection and fire alarm
systems.
Part
18:
Input/output
devices.
European Union
directives
TX
RADIO
WD
RESET
HELP
RX
ON
1 2 3 4 5 6 7 8
BACK
POWER
FAULT
ISOLATE
S
CR
+
-
LOOP IN
S
CR
LOOP OUT
+
-
1 2 3 4 5 6 7
3V3
TX
RX
0V
Operating temperature
-10 to +55 °C
Storage temperature
5 to 30 °C
Humidity
0 to 95% non-condensing
Supply
Powered from the zone interface monitor
Current drawn from
connected panel
(max.)
6 mA
Voltage
(max.)
50 VDC
IP rating
IP65
(when fitted inside zone interface monitor)
Dimensions
(W x H x D)
110 x 50 x 10 mm
Weight
0.05
kg
Location
Type A: For indoor use
TX
RADIO
WD
RESET
HELP
RX
ON
1 2 3 4 5 6 7 8
BACK
POWER
FAULT
ISOLATE
S
CR
+
-
LOOP IN
S
CR
LOOP OUT
+
-
1 2 3 4 5 6 7
3V3
TX
RX
0V
OUTPUT 2
OUTPUT 1
3VDC SET RST
INPUT 1 INPUT 2
LED
ENABLE
PO
WER
IN
PUT
1
IN
PUT
2
FAULT
CLOSED
0
1
1
64
F-SAFE
N/O COM N/C
SERIAL NO
LOGON
IP- IP+ IP- IP+
3VDC SET RST
N/O COM N/C
EXPAN1
EXPAN2
RELA
Y ON
RELA
Y ON
2
4
8
16
32
ANTENNA
KEEP CABLES AWAY FROM THIS AREA
SOUNDER
FAULT
ZONE
EOL L1 L2 EOL L1 L2
ALARM
RES
EOL L1 L2
(+) (-)
(+) (-) (+) (-) (+) (-) (+) (-)
(+) (-)
(+) (-)
SOUNDERS
FAULT
ZONE/RESET
EOL L1 L2 EOL L1 L2
ALARM
RES
EOL L1 L2
(+) (-)
(+) (-) (+) (-) (+) (-) (+) (-)
(+) (-)
(+) (-)
6 Connection wiring continued
LOOP IN
24V OUT
- +
SOUNDER
+ -
ZONE
+ -
+ -
+ -
1
3
2
1
= Sounder circuit EOL resistor
2
= Alarm triggering resistor
3
= Zone circuit EOL resistor
6 Connection Wiring continued
Option 1
Wired to provide fault
notification on the
conventional fire panel’s
SOUNDER CIRCUIT
Option 2
Wired to provide fault
notification on the
conventional fire panel’s
ZONE CIRCUIT
OUTPUT 2
OUTPUT 1
3VDC SET RST
INPUT 1 INPUT 2
LED
ENABLE
PO
WER
IN
PUT
1
IN
PUT
2
FAULT
CLOSED
0
1
1
64
F-SAFE
N/O COM N/C
SERIAL NO
LOGON
IP- IP+ IP- IP+
3VDC SET RST
N/O COM N/C
EXPAN1
EXPAN2
RELA
Y ON
RELA
Y ON
2
4
8
16
32
ANTENNA
KEEP CABLES AWAY FROM THIS AREA
SOUNDER
FAULT
ZONE
EOL L1 L2 EOL L1 L2
ALARM
RES
EOL L1 L2
(+) (-) (+) (-) (+) (-) (+) (-) (+) (-)
(+) (-)
(+) (-)
SOUNDERS
FAULT
ZONE/RESET
EOL L1 L2 EOL L1 L2
ALARM
RES
EOL L1 L2
(+) (-)
(+) (-) (+) (-) (+) (-) (+) (-)
(+) (-)
(+) (-)
LOOP IN
24V OUT
- +
SOUNDER
+ -
ZONE
+ -
1
3
2
1
= Sounder circuits EOL resistor
2
= Zone circuits EOL resistor
3
= Alarm triggering resistor
14
0905
Zone interface
monitor
(ZIM)
with conventional
interface card
(CIC)
fitted
Zone interface
monitor
(ZIM)
with conventional
interface card
(CIC)
fitted
Conventional
fire panel
Conventional
fire panel
Wireless
zone
monitor
(WZM)
Wireless
zone
monitor
(WZM)
Specification
Regulatory information
EMS declares that this device is in compliance
with Directive 2014/53/EU. The full text of
the EU declaration of conformity is available
at the following internet address:
www.emsgroup.co.uk
2012/19/EU
(WEEE directive):
Products marked with this symbol cannot be
disposed of as unsorted municipal waste in
the European Union. For recycling, return
this product to your local supplier upon
purchase of equivalent new equipment, or
dispose of it at designated collection points.
For more information see
www.recyclethis.info
©2021 EMS Ltd. All rights reserved Page 2 of 2
TSD147-99 Iss 6 15/12/2021 AJM