EMS 53-5414 Installation And Programming Instructions Download Page 14

EMS 5000 FIREPOINT 

 

©2015 EMS Security Group Ltd. All rights reserved.                                 TSD244 Iss 3 25/06/15 AJM

 

14 

 

Summary of Contents for 53-5414

Page 1: ...5000 VHF UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS 53 5414 53 5428 ...

Page 2: ...LS TEST EQUIPMENT 4 3 RECEIVER POSITION 4 4 UHF REMOTE RECEIVER RELEVANT HIGH GAIN AERIALS 4 5 VHF REMOTE RECEIVER RELEVANT HIGH GAIN AERIALS 5 6 ELECTRICAL INSTALLATION 5 6 1 UHF REMOTE RECEIVER 5 6 2 VHF REMOTE RECEIVER 6 7 SOFTWARE CONFIGURATION 7 8 MAIN CONTROL PANEL ENGINEERS MENU STRUCTURE 11 9 TESTING THE SYSTEM 12 10 CONTROLLER INFORMATION 15 ...

Page 3: ...verall range coverage of the system This information is then sent to the control panel via cable FP200 A maximum of 28 remote receivers can be connected to the Control Panel A block diagram of a system using the UHF remote receiver is shown in Figure 1 The Model 53 5414 is a VHF remote receiver capable of receiving VHF signals directly from all types of detectors thus improving the overall range c...

Page 4: ...stem is operating The actual range achieved is determined by local site conditions For range improvements high gain aerials can be attached to the remote receivers The table below indicates relevant aerials 4 UHF Remote Receiver Relevant high gain aerials 5 5501 High gain aerial c w 3 metres of cable and bracket 5 5501 BP10 High gain aerial c w 10 metres of cable wall mounting bracket and extensio...

Page 5: ...emote receiver 53 5428 should be wired as shown in the supplied drawing PO3045 The following paragraphs outline the installation in a step by step format Remove the four lid retaining screws situated on the front cover The front section of the unit can now be removed Four fixing holes are available for the unit s installation These are clearly visible on the outside of the casing Offer the back bo...

Page 6: ...ll and check that the rear tamper switch operates Should the microswitch not operate remove the unit from the wall and carefully adjust the microswitch arm Once the microswitch operates correctly the unit can be fixed to the wall and all external wiring connections made The diagram P03077 shows the wiring connections required for the remote receiver Only those cables needed to make the remote rece...

Page 7: ...ill now display 5 Enter your PIN number Engineering default 221100 and press the YES key The screen will now display 6 Press any key and the screen will display 7 Press the key until the screen displays 8 Press the YES button and the screen will display 9 Press the key until the screen displays 10 Press the YES key and the screen will display Panel In Access DATE TIME Options Passwords Time and Da...

Page 8: ...S key and the screen will display 20 Press the NO key once and the screen will display 21 Press the key until the screen displays Master Setup Polling Baudrate Auto Re online YES Select TIME Reset Security Reset System Lan Options Yes Select Time Main Menu Pins Access System Support Yes Select Time System Support Serial Comms Pager Setup Yes Select Time Serial Comms Device Table Re start Bus YES S...

Page 9: ...on and the screen will display 30 Press the key until the screen displays 31 Press the YES button and the screen will display 32 The collector should be set to ENABLED press the YES key to change its status Once set to Enabled press the NO key The screen will display Re initialising Bus Please wait Done Push any key TIME Device Table Re start Bus Re Online Device YES Select TIME Printer Redirect M...

Page 10: ...et to Enabled press the NO key The screen will display 42 Press the NO key twice and the screen will display 43 Now turn the control keyswitch to the OFF position and the screen will display The Remote Receiver is now programmed to the System Logging Remote Rxers Ext Comms Yes Select Time Checksum Data Network Router Radio Lan Yes Select Time NETWORK ROUTER Setup local NUA View network NUA Yes Sel...

Page 11: ...Setup Pager 232 Redir Aux 232 Redirect Printer Redirect Monitor Comms Delete Device Re Initialising Bus Please Wait Push Any Key Master Setup Polling Baudrate Auto Re online Port to use Remote Receivers Receivers Found Enable Receiver Enable Collector Monitor traffic HEAP00 AUX 00 PGR 00 REM000 MAS010 T00 00 I00 L00 R00 S00 C00 Master Port 1 0 Off 1 RS485 2 PAGER 232 Enabled Push YES to change Pus...

Page 12: ...y a particular remote indicates a poor connection poor screening or the cable passing near enough to a data cable to introduce interference onto the bus Once VHF Remote units have been installed and are communicating with the Control Panel devices should now be tested from their fixed positions Once UHF Remote units have been installed and are communicating with the Control Panel the transponder u...

Page 13: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD244 Iss 3 25 06 15 AJM 13 ...

Page 14: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD244 Iss 3 25 06 15 AJM 14 ...

Page 15: ...12volt 7Ah batteries supplied EMS only recommend Yucel Model No NP7 12 or a battery of equivalent specification Recommended battery replacement intervals 5 years TECHNICAL INFORMATION FOR THE VHF Remote Receiver Dimensions 390mm x 320mm x 80mm Operating Frequencies VHF 173 2 173 5 MHz Receiver Operating Temperature 10 to 55 degrees C Humidity Up to 75 non condensing Channel Spacing 25 kHz Supply 2...

Page 16: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD244 Iss 3 25 06 15 AJM 16 ...

Reviews: