Empire RH-25-7 Installation Instructions And Owner'S Manual Download Page 5

Introduction

Always consult your local Building Department regarding regula-

tions, codes or ordinances which apply to the installation of a vented 

room heater.

Instructions to Installer

1.  Installer must leave instruction manual with owner after instal-

lation.

2.   Installer must have owner fill out and mail warranty card sup

-

plied with vented room heater.

3.   Installer should show owner how to start and operate vented 

room heater and thermostat.

Warning:

Any change to this vented room heater or its controls can 

be dangerous.  Any safety screen or guard removed for 

servicing a vented room heater must be replaced prior to 

operating the vented room heater.

General Information

 

This series is design certified in accordance with American National 

Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian 

Standards Association, as a Vented Room Heater and must be 

installed according to these instructions.

Any alteration of the original design, installed other than as 

shown in these instructions or use with a type of gas not 

shown on the rating plate is the responsibility of the person 

and company making the change.

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

Notice:

  During initial firing of this unit, its paint will bake out and 

smoke will occur.  To prevent triggering of smoke alarms, ventilate 

the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other 

combustible material, 

other than wood flooring, 

the appliance shall 

be installed on a metal or wood panel extending the full width and 

depth of the appliance.

The base referred to above does not mean the fire-proof base as 

used on wood stoves.  The protection is primarily for rugs that may 

be extremely thick and light-color tile that can discolor.
Floor pad is available from Empire Comfort Systems, Inc., Part 

Number RH425.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip

-

ment  or accessories and repair and servicing of equipment shall 

be  performed  only  by  a  qualified  agency.    The  term  “qualified 

agency” means any individual, firm, corporation, or company which 

whether in person or through a representative is engaged in and 

is responsible for (a) the installation or replacement of gas piping 

or (b) the connection, installation, repair or servicing of equipment, 

who is experienced in such work, familiar with all precautions re-

quired and has complied with all the requirements of the authority 

having jurisdiction.

state of Massachusetts: 

The installation must by made 

by  a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

The installation must conform to local codes or,  in the absence 

of local codes,  with the 

National Fuel Gas Code, ANSI Z223.1 */

Canadian Installation Code, CAN/CGA B149.

*Available from the American National Standards Institute, Inc., 11 

West 42nd St.,  New York, NY  10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings 

should be reduced at the rate of 4 percent for each 1,000 feet (305m) 

above sea level.  

Canadian High Altitudes 

for locations having an 

elevation above mean sea level between 2,000 feet (610m) and 

4,500 feet (1370m), the manifold pressure is to be decreased from 

4.0" w.c. (.996kPa) to 3.2" w.c. (.797kPa) for Natural Gas and from 

10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa) for Propane Gas.

Model

RH-25

RH-35

Input BTU.HR (KW/H)

25,000 (7.3)

35,000 (10.3)

Height

26" (660mm)

26" (660mm)

Width

37" (940mm)

37" (940mm)

Depth including diverter

18 3/8" (467mm)

18 3/8" (467mm)

Gas Inlet Pipe

1/2" (13mm)

1/2" (13mm)

Size of flue collar

4" (102mm)

4" (102mm)

Floor to top of collar on vertical position of Draft Diverter

22 15/16" (583mm)

22 15/16" (583mm)

Floor to center of collar on horizontal position of Draft 

Diverter

18 3/16" (462mm)

18 3/16" (462mm)

Accessories

Blower Package

DRB-1

DRB-1

Floor Pad

RH425

RH425

sPECIFICATIONs

INTRODUCTION

30500-4-0115

Page 5

Summary of Contents for RH-25-7

Page 1: ...mable vapors and liquids in the vi cinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your b...

Page 2: ...VERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER 9 THERMOSTAT OPERATION 9 LIGHTING INSTRUCTIONS 10 PILOT FLAME CHARACTERISTICS 11 MAIN BURNER FLAME CHARACTERISTICS 11 MAINTENANCE 12 TROUBLESHOOTING 12 M...

Page 3: ...of the room heater be kept clean Do not put anything around the heater that will obstruct the flow of combustion and ventilation air See clearances Do keep the appliance area clear and free from combu...

Page 4: ...service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of n...

Page 5: ...s available from Empire Comfort Systems Inc Part Number RH425 Qualified Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing...

Page 6: ...t of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect Figure 2 Method of Installing a Tee Fitting Sediment...

Page 7: ...be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brick or stone co...

Page 8: ...o fully in and be cemented The flue pipe MUST NOT go too far into the chimney It should be cut off as it will interfere with normal venting Flue pipe MUST NOT have any downward sloping sections dips o...

Page 9: ...witch from the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole cover plate and two 2 1 2 screws for attachment of vent safety switc...

Page 10: ...ng To Turn Off Gas To Appliance A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance ar...

Page 11: ...ner flame with a larger lighter blue secondary flame The burner flame may have yellow tips when hot Dust in the combustion air will produce an orange or red flame Do not mistake the orange or red flam...

Page 12: ...ased a Pilot flame not covering the thermocouple properly b Defective thermocouple c Defective magnet in the safety section of valve 4 Poor thermostat control a Thermostat needs calibrating b Defectiv...

Page 13: ...listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Numb...

Page 14: ...6 5 29 12 4 3 1 29 30 11 13 14 15 16 10 9 9 17 19 20 21 22 23 24 25 26 28 27 INSULATION 2 7 8 INSULATION RH 35 ONLY 18 TO PILOT PARTS VIEW 30500 4 0115 Page 14...

Page 15: ...25 7 LPG 12 29089 Inlet Tubing Assembly 13 RH818 Diverter Assembly 14 RH801 Down Draft Shield 15 RH799 Diverter Plate 16 DV 951 Casing Top 17 32184 Inner Casing Assembly RH 25 7 17 32252 Inner Casing...

Page 16: ...5 For DV 25 1 2 SG and DV 35 1 2 SG replace heat shield and casing front Attention Wiring harness on blower is factory assembled and installed If wiring harness becomes disassembled use the follow in...

Page 17: ...ed CAUTION Labelallwirespriortodisconnectionwhenservicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Warning Unplugging of blower accesso...

Page 18: ...led check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use mi...

Page 19: ...APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes 30500 4 0115 Page 19...

Page 20: ...ems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your d...

Page 21: ...s tenter d allumer d appareil Ne touchez a aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b ti ment o vous vous trouvez Appelez imm diatement votre fournisseur de gaz depuis...

Page 22: ...nt du Thermostat 8 instructions d allumage 9 Aspect Convenable de la Flamme de la Veilleuse 10 Aspect Convenable de la Flamme du Br leur Principal 10 maintenance 11 D tection des d fectuosit s 11 VUE...

Page 23: ...diateur qui pourrait obstruer le d bit de combustion et la ventilation d air Voir les espaces libres Les mat riaux combustibles la gazoline ou les vapeurs et liquides inflammables ne doivent jamais tr...

Page 24: ...ler Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Nepasouvrirlessoupapesd approvisionnementdegazm mesivous ne le sentez plus Ne retourner pas...

Page 25: ...e le feu comme il est utilis pour les po les bois La protection est pour les tapis extr mement pais et les tuiles de couleur qui pourraient se d colorer UneplateformepourradiateurestdisponiblechezEmpi...

Page 26: ...agesoitinstall epr sdel entr e de gaz Ceci doit consister en une longueur de tuyau vertical qui sera rac cord par un T sur la ligne de gaz et termin au bas par un bouchon La condensation et les partic...

Page 27: ...un chappement convenable sous des conditions normales Dans les b ti ments de construction conventionnelle de brique ou de pierre sans fen tre et porte tanche l infiltration est normalement ad quate p...

Page 28: ...vent L280 du coupe tirage 2 l int rieur de l enveloppe jaune d instructions vous trouverez une plaque de 1 1 2 x 2 1 4 38mm x 57mm pour couvrir le trou de l interrupteurdes ret del ventetdeux 2 visde...

Page 29: ...rr ter Lire les informations de s curit la gauche de cette tiquette 2 Mettre le thermostat son plus bas r glage 3 teindre tout pouvoir lectrique l appareil si applicable 4 Pousser l g rement le bouton...

Page 30: ...leuse Aspect Convenable de la Flamme du Br leur Principal Figure 5 Il y aura une petite flamme bleue int rieure avec une flamme secondaire bleue p le plus large La flamme du br leur peut avoir une poi...

Page 31: ...pas le thermocouple convenablement b Thermocouple d fectueux c Un aimant d fectueux dans la partie de s curit de la valve 4 Le contr le du thermostat est inefficace a Thermostat a besoin d tre calibr...

Page 32: ...VUE DES PI CES 6 5 29 12 4 3 1 29 30 11 13 14 15 16 10 9 9 17 19 20 21 22 23 24 25 26 28 27 ISOLATION 2 7 8 ISOLATION SEULEMENT POUR RH 35 18 POUR LA VEILLEUSE 30500 4 0115 Page 12...

Page 33: ...2 29089 Entr e Assembl e tubes 13 RH818 Assemblage du coupe tirage 14 RH801 cran contre les courants d air 15 RH799 Plaque du coupe tirage 16 DV 951 Paroi du dessus 17 32184 Assemblage de la paroi int...

Page 34: ...diateurs foyers et barbecues Able Distributors 2501 North Central Avenue Chicago IL 60639 T l phone 773 889 5555 Sans frais 800 880 2253 T l copieur 773 466 1118 Website www abledistributors com Pi ce...

Page 35: ...SG et DV 35 1 2 SG replacer l cran de chaleur et la paroi du devant ATTENTION Le harnais de fils lectriques sur la soufflerie est assembl et install l usine Si le harnais de fils lectriques se d sasse...

Page 36: ...r que le fonctionnement soit conven able apr s l entretien AVERTISSEMENT D brancher l accessoire de la soufflerie n arr tera pas le cycle de l appareil de chauffage Pour fermer l appareil 1 Tourner le...

Page 37: ...pour attester de la date d achat et tablir la p riode de garantie Acc s imm diat l appareil pour la r paration Ce qui n est pas couvert Dommages pouvant r sulter de l emploi de l emploi abusif ou d un...

Page 38: ...MAINTENANCE HISTORIQUE DE L APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectu notes 30500 4 0115 Page 18...

Page 39: ...MAINTENANCE HISTORIQUE DE L APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectu notes 30500 4 0115 Page 19...

Page 40: ...burg Ave Belleville IL 62220 Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou de r paration veuillez con...

Reviews: