39910-1-0919
Page 10
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Refer to
Figures 9, 10, 11 and 12
for measurements in order to locate (4) mounting holes on wall.
Figures 9, 10, 11 and 12
are the
front views of the heaters.
1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).
CEILING
SIDE WALL
8” MIN.
8” MIN.
36” MIN
2” MIN
FLOOR
Figure 8 (SR-30W)
Figure 9 (SR-6W)
Figure 10 (SR-10W)
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
FLOOR
4 1/32”
(102mm)
2” MIN (51mm)
18 7/8”
(479mm)
22”
(559mm)
OUTLINE OF
OUTER CASING
1 3/32”
(28mm)
2”
(51mm)
2”
(51mm)
7 13/16”
(198mm)
11 13/16”
(300mm)
11 13/16”
(300mm)
7 13/16”
(198mm)
2”
(51mm)
2”
(51mm)
1 3/32”
(28mm)
18 7/8”
(479mm)
OUTLINE OF
OUTER CASING
22”
(559mm)
FLOOR
4 1/32” MIN
(102mm)
2” MIN (51mm)
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
SR-30W CLEARANCES
WALL MOUNT INSTALLATION