Empire Heating Systems SR-10W-1 Installation Instructions And Owner'S Manual Download Page 1

Page 1

UNVENTED

ROOM HEATER

MODELS

SR-6W-1 SR-10W-1 SR-18W-1 SR-30W-1

SR-30W SHOWN

INSTALLER: 

Leave this manual with the appliance.

CONSUMER: 

Retain this manual for future reference.

WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death or 

property damage.

—  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do 

not use any phone in your building.

•  Leave the building immediately.

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department.

—  Installation and service must be 

performed by a qualified installer, 

service agency or the gas supplier.

This appliance may be installed in an aftermarket, 

permanently located, manufactured (mobile) home, 

where not prohibited by local codes.

This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases.

This is an unvented gas-fired heater. It uses air 

(oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventilation 

air must be provided. Refer to page 6.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water  vapor  is  a  by-product  of  gas  combustion. 

An unvented room heater produces approximately 

one (1) ounce (30ml) of water for every 1,000 BTU’s 

(.3KW’s) of gas input per hour. Refer to page 6.

WARNING

If not installed, operated and maintained 

in  accordance  with  the  manufacturer’s 

instructions, this product could expose you 

to substances in fuel or from fuel combustion 

which can cause death or serious illness.

WARNING

“FIRE, EXPLOSION, AND ASPHYXIATION HAZARD

Improper adjustment, alteration, service, 

maintenance, or installation of this heater or 

its controls can cause death or serious injury.

Read and follow instructions and precautions 

in User’s Information Manual provided with 

this heater.”

INSTALLATION INSTRUCTIONS 

AND OWNER'S MANUAL

Summary of Contents for SR-10W-1

Page 1: ...ile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases This is an unv...

Page 2: ...11 Optional Floor Stand Installation 12 Lighting Instructions 13 Main Burner Flame Characteristics 14 Important Soot Prevention Steps 15 Pilot Flame Characteristics 16 Main Burner Operation 16 Applian...

Page 3: ...or to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the burner...

Page 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorpti...

Page 5: ...of gas piping or b the connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all precautions required and that has complied with all t...

Page 6: ...ing the volume of a typical area in which the SR 18W may be located and for determining if this area fits the definition of an unconfined space The maximum input of the SR 18W is 18 000 Btu per hour B...

Page 7: ...n the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of...

Page 8: ...WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 12 MAX 305mm 0 0mm CLEARANCE TO REAR WALL SIDE VIEW 2 MIN 51mm FLOOR CEILING SIDE WALL WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 6 MIN 152mm 6 MIN 1...

Page 9: ...ust be maintained Left side 6 inches 152mm Right side 6 inches 152mm Do not install in alcove or closet Rear wall 0 inches 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection abov...

Page 10: ...9 10 11 and 12 for measurements in order to locate 4 mounting holes on wall Figures 9 10 11 and 12 are the front views of the heaters 1 Remove lower louver from casing assembly 2 screws 2 Remove refle...

Page 11: ...10 x 1 25mm screws provided into the plastic expansion anchors Do not completely tighten screwheads to the plastic expansion anchors leave a 1 8 3mm gap between screwheads and plastic expansion ancho...

Page 12: ...Attach floor stand to heater with 4 screws provided with floor stand 3 Connect the gas line Floor stand can not be used in a bathroom or bedroom installation SR 6W must be wall mounted in a bathroom...

Page 13: ...d pilot the pilot is at tached at the bottom of the burner assembly 6 Turn manual gas control knob counterclockwise to PILOT 7 Push in manual gas con trol knob all the way and hold in Repeatedly push...

Page 14: ...inside the casing assembly and main burner assembly Use the following procedure to inspect the casing assembly and main burner as sembly 1 Turn OFF gas supply to the heater 2 Turn OFF electric supply...

Page 15: ...u have pets or excessive dust more frequent cleaning may be necessary See main burner flame characteristics section in this manual 1 Ensure burner venturi and air shutter are free of dirt lint animal...

Page 16: ...N it will continue to operate until the owner manually turns the main burner OFF Description of Manual Gas Control Knob OFF position PILOT position SR 6W Position 1 Will have one plaque in operation t...

Page 17: ...electrical supply to the heater if optional blower is installed in heater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Disconnect inlet suppl...

Page 18: ...ntrol knob in pilot position not completely depressed or held in long enough b Thermocouple not tightened into gas control tighten thermocouple c Pilot flame not surrounding thermocouple clean pilot s...

Page 19: ...39910 1 0919 Page 19 This page intentionally left blank...

Page 20: ...AS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 INL...

Page 21: ...39910 1 0919 Page 21 SR 6W parts View...

Page 22: ...GAS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 IN...

Page 23: ...39910 1 0919 Page 23 SR 10W parts View...

Page 24: ...18 R 2498 MAIN BURNER ORIFICE PROPANE 3 REQUIRED 19 R 2330 BURNER 20 SR 082 TUBING GAS VALVE TO BURNER TWO 21 SR 217 TUBING INLET REGULATOR TO GAS VALVE 22 10753 INLET REGULATOR BRACKET 23 R 5097 INL...

Page 25: ...39910 1 0919 Page 25 SR 18W parts View...

Page 26: ...HOLDER 5 REQUIRED 20 R 2315 MAIN BURNER ORIFICE NATURAL 5 REQUIRED 20 R 2498 MAIN BURNER ORIFICE PROPANE 5 REQUIRED 21 R 2329 BURNER 22 10753 INLET REGULATOR BRACKET 23 R 5097 INLET REGULATOR NATURAL...

Page 27: ...39910 1 0919 Page 27 SR 30W parts View...

Page 28: ...ot wire on motor wire harness OPTIONAL BLOWERS SRB 18W and SRB 30W for Unvented Room Heaters SR 18W and SR 30W HEAT SHIELD GROUND WIRE SCREW REFLECTOR AND LOUVERS ARE REMOVED FROM CASING ASSEMBLY ON O...

Page 29: ...met with brass bushing or black rubber grommet with brass bushing onto end of blower wheel shaft Attention The red rubber grommet with brass bushing or the black rubber grommet with brass bushing must...

Page 30: ...SING 2 R 2522 ON OFF SWITCH 3 R 2395 WIRE ASSEMBLY 4 R1468 BUSHING HEYCO SR5KN4 5 R2099 CORD SET ASSEMBLY 6 39873 BLOWER PAN SR 18W 6 39874 BLOWER PAN SR 30W 7 R1449 RUBBER GROMMET 4 REQUIRED 8 R1454...

Page 31: ...purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the...

Page 32: ...ppliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to ver...

Reviews: