VENT SAFETY SHUTOFF SYSTEM

This heater must be properly connected to a venting system. This 

heater is equipped with a vent safety shutoff system.

This appliance needs fresh air for safe operation and must be 

installed so there are provisions for adequate combustion and 

ventilation air.

This room heater is equipped with a vent safety switch. The vent 

safety switch will cause gas flow to the pilot to “shut off” due to 

improper venting or a blocked flue.
If the vent safety switch continues to “shut off” the gas flow to 

the pilot, a qualified service person must be contacted to inspect 

for improper venting, blockage in the vent pipe or the vent safety 

switch for being defective.

Warning:

Operation  of  this  heater,  when  not  connected  to  a  

properly  installed  and  maintained  venting  system  or  

tampering with the vent safety shutoff system, can result in 

carbon monoxide (CO) poisoning and possible death.

REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER

This room heater has a reversible draft diverter. The draft diverter 

is installed in the vertical position at the factory. Please use the 

following steps to change the draft diverter from the vertical 

positing to the horizontal position.

1. Remove L280 vent safety switch from the draft diverter.

2. Inside your yellow instruction envelope will be a 1 1/2” x 2 

1/4” (38mm x 51mm) vent safety switch hole cover plate and 

two (2) 1/2” screws for attachment of vent safety switch hole 

cover plate to the draft diverter. Attach vent safety switch hole 

cover plate over hole on the draft diverter from which the L280 

vent safety switch was removed.

3. Remove two (2) screws at bottom of draft diverter and lift 

upward to remove draft diverter from the draft diverter plate. 

Rotate draft diverter into the horizontal position and slide back 

into the draft diverter plate. Attach two (2) screws into bottom 

of the drafter diverter.

4. Remove vent safety switch hole knockout and two (2) knockouts 

for screws on opposite side of draft diverter.

5. Attach L280 vent safety switch to the draft diverter.

6. Repositioning of the draft diverter is completed.

DRAFT DIVERTER CAN BE EITHER A VERTICAL VENT 

OR HORIZONTAL VENT

Figure 4

THERMOSTAT OPERATION

To turn on burner, rotate dial knob toward setting number 7. To 

shut down burner, rotate dial knob toward setting number 1.
The dial numbers 1 to 7 correspond to 50

o

 to 90

o

F (10

o

 to 32

o

C). 

This temperature at the bulb thermostat, not the room tempera-

ture. The owner is advised to determine the particular heat setting 

that is desired for comfort, as heating requirements are different 

for every owner.

Attention: 

If no heat is desired, turn the gas control knob to the 

PILOT position.

Summary of Contents for RH-50-6

Page 1: ...s supplier s instructions If you cannot reach yourgas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal in jury or loss of life Installer Please leave these instructions with the consume...

Page 2: ...Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Maintenance 11 Troubleshooting 11 How to Order Repair Parts 12 Parts List RH 50 RH 65 12 Parts View RH 50 RH 65 13 Parts List RH 50C RH 65C 14 Parts View RH 50C RH 65C 15 Optional Blower Installation Instructions 16 17 Service Notes 18 SECT...

Page 3: ... before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the flow of combustion and ventilation air See clearances DO keep t...

Page 4: ...n occur in new tanks or reinstalled old tanks if they are filled and allowed to set too long before refilling Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade If such conditions are suspected to exist a periodic sniff test of the gas is advisable If you have any question about the gas odor call your LP gas dealer A periodic sniff test...

Page 5: ...ve is engaged in and is respon sible for 1 the installation or replacement of gas piping or b the connection installation repair or servicing of equipment who is experienced in such work familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction The installation must conform with local codes or in the absence of local codes with the Natio...

Page 6: ...est with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which conde...

Page 7: ...mbustion Air Room heaters shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brick or stone construction without tight storm windows and doors infiltration is normally adequate to provide for combustion and draft hood dilution Whereappliancesareinstalledinaconfine...

Page 8: ... switch from the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole cover plate and two 2 1 2 screws for attachment of vent safety switch hole cover plate to the draft diverter Attach vent safety switch hole cover plate over hole on the draft diverter from which the L280 vent safety switch was removed 3 Remove two 2 screws at bottom...

Page 9: ...the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 7 Find pilot the pilot is attached to front of burner 8 Turn gas control knob counterclockwise to IGN 9 Depress and turn gas control knob counterclockwise to PILOT Aspark is produced when gas control knob is turned between IGN and PILOT Repeatedly depress and turn gas c...

Page 10: ...IN BURNER FLAME CHARACTERISTICS There will be a short blue inner flame with a larger lighter blue secondary flame The burner flame may have yellow tips when hot Dust in the combustion air will produce and orange or red flame Do not mistake the orange or red flame for an improper yellow flame The flame will be proper if the factory set pressure and orifice are used After use cleaning may be required for th...

Page 11: ...ot be removed from main burner by using primary air adjustment bolt the air shutter bracket can be pivoted upward to allow additional primary air to enter burner throat On Propane gas if a whistling noise resonation occurs screw the air adjustment bolt into the burner throat to eliminate the whistling noise resonation TROUBLESHOOTING 1 Impossible to light pilot a If using piezo ignitor check elect...

Page 12: ... 6 LPG 5 11707 Louver RH 50 6 3 required RH 65 6 4 required 27 11746 Valve Bracket 6 11745 Casing Back 28 R 6101 Gas Valve Nat 7 RH 652 Combustion Chamber Assembly RH 50 6 28 R 6102 Gas Valve LPG 7 RH 626 Combustion Chamber Assembly RH 65 6 29 11743 Control Rod 8 RH 654 Chamber Shield Right RH 50 6 30 11700 Control Rod Bracket 8 RH 655 Chamber Shield Right RH 65 6 31 R 6096 Knob Adaptor Set 9 1172...

Page 13: ...12822 3 0406 Page 13 PARTS VIEW RH 50 RH 65 ...

Page 14: ...7 Main Burner Orifice RH 50C 1 LPG 8 RH 654 Chamber Shield Right RH 50C 1 23 11746 Valve Bracket 8 RH 655 Chamber Shield Right RH 65C 1 24 R 6101 Gas Valve NAT 9 11721 Casing Side RH 50C 1 24 R 6102 Gas Valve LPG 9 11722 Casing Side RH 65C 1 25 11743 Control Rod 10 RH 618 Inner Front 26 11700 Control Rod Bracket 11 RH 625 Bottom Reflector RH 50C 1 27 R 6096 Knob Adaptor Set 11 RH 660 Bottom Reflector...

Page 15: ...12822 3 0406 Page 15 PARTS VIEW RH 50C RH 65C ...

Page 16: ...tep 1 in the even the blower housing is removed from room heater Attention Bottom reflector and rear shield must be at tached to bottom assembly whenever the blower housing in removed from the room heater and the room heater is in operation 5 Remove switch box cover from the switch box by removing the 8 x 1 4 6mm hex head screw 6 There are two screw holes on the lower back of the combus tion chambe...

Page 17: ...l electrical source is utilized This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded ...

Page 18: ...12822 3 0406 Page 18 SERVICE NOTES ...

Page 19: ...12822 3 0406 Page 19 SERVICE NOTES ...

Page 20: ...22 3 0406 Page 20 SERVICE NOTES Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ...

Reviews: