Empire Heating Systems BF-10-3 Installation Instructions And Owner'S Manual Download Page 15

35965-0-0615

Page 15

PLEASE NOTE:  When ordering parts, it is very important that  part number and description of part coincide.

  USE ONLy MANUFACTURER'S REPLACEMENT PARTS.  USE OF ANy OThER PARTS COULD CAUSE INjURy OR DEATh.

PARts LIst

1

13347

CASING SIDE ASSEMBLY - LEFT (BF-10 )

1

13348

CASINg SIDE ASSEMBLy - LEFT  

(BF-20, BF-30)

2

SR-090

CASING BACK (BF-10 BF-20)

2

SR-041

CASING BACK (BF-30)

3

R-2313 PIEZO IgNITOR

4

11231

FAN CONTROL BRACKET (BF-10)

5

SR-008 CASINg SIDE ASSEMBLy - RIghT

6

R-1992 BULB CLIP

7

SR-076

CASING LOUVER-TOP (BF-10 BF-20)

7

SR-017

CASING LOUVER-TOP (BF-30)

8

SR-077

HEAT SHIELD (BF-10 BF-20)

8

SR-018

HEAT SHIELD (BF-30)

9

SR-075 REFLECTOR ShIELD REAR  

(BF-10, BF-20)

9

SR-016

REFLECTOR SHIELD REAR (BF-30)

10

10478

REAR SHIELD (BF-10, BF-20)

10

10420

REAR SHIELD (BF-30)

11

35956

REFLECTOR ASSEMBLy  

(BF-10, BF-20) INCLUDES 9 AND 10

11

35957

REFLECTOR ASSEMBLY (BF-30) 

INCLUDES 9 AND 10

12

10467

CASINg LOUVER-BOTTOM ASSEMBLy 

(BF-10, BF-20)

12

10479

CASINg LOUVER-BOTTOM ASSEMBLy 

(BF-30)

13

R-4979

CHROME GRILL (BF-10, BF-20)

13

R-4980

CHROME GRILL (BF-30)

14

R-4993

GLASS (BF-10 BF-20)

14

R-4994

GLASS (BF-30)

15

R-2784 INLET REgULATOR - NAT

15

R-2480 INLET REgULATOR - LPg

16

10753

INLET REgULATOR BRACKET

17

12442

TUBING - GAS VALVE TO BURNER (BF-

10, BF-20)

17

12443

TUBING - GAS VALVE TO BURNER (BF-

30)

18

12437

TUBINg - INLET REgULATOR TO gAS 

VALVE

19

R-6563

GAS VALVE (NAT & LPG)

20

SR-113 VALVE BRACKET

21

10460

BURNER BRACKET - LEFT

22

10422

BURNER (BF-10, BF-20)

22

10481

BURNER (BF-30)

23

10424

AIR SHUTTER (BF-10 ONLY)

24

10461

BURNER BRACKET - RIghT

25

P-214

MAIN BURNER ORIFICE (BF-10 NAT)

25

P-193

MAIN BURNER ORIFICE (BF-10 LPG)

25

P-252

MAIN BURNER ORIFICE (BF-20 NAT)

25

P-182

MAIN BURNER ORIFICE (BF-20 LPG)

25

P-211

MAIN BURNER ORIFICE (BF-30 NAT)

25

P-185

MAIN BURNER ORIFICE (BF-30 LPG)

26

P-212

ORIFICE hOLDER

27

10424

AIR SHUTTER (BF-10 NAT & LPG) (BF-20 

& BF-30 LPG ONLY)

28

10539

TUBINg - gAS VALVE TO PILOT  

(BF-10 BF-20)

28

10540

TUBINg - gAS VALVE TO PILOT  

(BF-30)

29

R-6306

PILOT ASSEMBLY (NAT ONLY) 

(INCLUDES 30 & 31)

29

R-6308

PILOT ASSEMBLY (LPG ONLY) 

(INCLUDES 30 & 31)

30

R-6310 PILOT ThERMOCOUPLE

31

R-6309 SPARK IgNITOR

32

R-2390 IgNITOR WIRE

33

SR-120 OPTIONAL SRS-18 FLOOR STAND KIT 

(BF-10, BF-20)

33

SR-115 OPTIONAL SRS-30 FLOOR STAND KIT 

(BF-30)

34

SR-122 OPTIONAL SRB-18T BLOWER KIT 

(BF-10 BF-20) 

 

(INCLUDES 34 THROUGH 41)

34

SR-116

OPTIONAL SRB-30T BLOWER KIT (BF-

30) (INCLUDES 34 THROUGH 41)

35

R-1454

BRASS BUSHING  (4 REQUIRED)

36

R-1499

RUBBER GROMMET (4 REQUIRED)

37

SR-196

BLOWER PAN (BF-10 BF-20)

37

SR-198

BLOWER PAN (BF-30)

38

VF-068 CORD SET ASSEMBLy

39

R-1468

BUSHING - HEYCO #SR5KN4

40

R-2395 WIRE ASSEMBLy

41

R-2503 FAN CONTROL

42

R-2396

BLOWER (INCLUDES MOTOR, FAN, AND 

FAN hOUSINg)

N/S

SR-219 BLOWER hARDWARE PACKAgE

N/S

SR-216 hARDWARE PACKAgE

N/S

R-1976  MIN. RATE SCREW NAT 1.60

N/S

R-1977 MIN. RATE SCREW LP 1.00

Index 

No.

Part No. description

Index 

No.

Part No. description

Summary of Contents for BF-10-3

Page 1: ...located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with ot...

Page 2: ...nd Ventilation Air 6 Gas Supply 7 Clearances 8 Optional Floor Stand Installation 8 Wall Mount Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilot Flame Characteristics 1...

Page 3: ...ree from combustible materials gasoline and other flammable vapors and liquids Warning Any change to this HEATER or its controlS can be dangerous Any safety screen or guard removed for servicing an ap...

Page 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Page 5: ...nstaller must have owner fill out and mail warranty card supplied with unvented room heater 3 Installer should show owner how to start and operate unvented room heater Always consult your local Buildi...

Page 6: ...rea in which the BF 20 may be located and for determining if this area fits the definition of an unconfined space The input of the BF 20 is 20 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Page 7: ...Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed...

Page 8: ...and meets requirement The base referred to in this section does not mean the fire proof base as used on wood stoves The protection is for rugs that are extremely thick and light colored tile Figure 5...

Page 9: ...20 1 8 511mm 2 51mm 2 51mm 22 559mm BF 30 Figure 7 BF 10 and BF 20 Figure 6 Refer to Figures 6 and 7 for measurements in order to locate 4 mounting holes on wall Figures 6 and 7 are the front views of...

Page 10: ...when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 4 through 8 10 Turn gas control knob counterclockwise to HI 11 Turn on all electric power to applianc...

Page 11: ...in burner is factory set at a 3 32 opening If yellow flames occur on main burner loosen 1 4 screw on air shutter in order to increase air shutter opening The slot on air shutter allows the air opening...

Page 12: ...ulb which is located at the casing assembly bottom adjusts the main burner flame between minimum input and maximum input BF 30 The gas control modulates from a minimum input of 8 500 Btu HR 2 5 KW H L...

Page 13: ...ore lower louver is replaced onto casing assembly To Remove Gas Valve From Casing Assembly 1 Turn off gas supply to the heater 2 Turn off electrical supply to the heater if optional blower SRB 18T or...

Page 14: ...ompletely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten thermocouple lea...

Page 15: ...AS VALVE 19 R 6563 GAS VALVE NAT LPG 20 SR 113 VALVE BRACKET 21 10460 BURNER BRACKET LEFT 22 10422 BURNER BF 10 BF 20 22 10481 BURNER BF 30 23 10424 AIR SHUTTER BF 10 ONLY 24 10461 BURNER BRACKET RIGH...

Page 16: ...35965 0 0615 Page 16 PARTS VIEW...

Page 17: ...using downward Place the bottom flange of the blower housing over the top edge of the top heat shield Insert the blower housing into the top portion of the heater by pivoting the blower housing upward...

Page 18: ...lect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to the heater 2 Tur...

Page 19: ...eater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwweb...

Page 20: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...