If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when 

lit. If the gas quality or pressure is low, contact your local gas supplier immediately.

  1.  When ignitor button is pressed, there is no spark at oDS/

pilot. 

a.  Ignitor electrode positioned wrong - Replace pilot.

b.  Ignitor electrode is broken - Replace pilot.

c.  Ignitor electrode not connected to ignitor cable - Reconnect 

ignitor cable.

d.  Ignitor cable pinched or wet. Keep ignitor cable dry - Free 

ignitor cable if pinched by any metal or tubing. 

e.  Broken ignitor cable - Replace ignitor cable.

f.  Bad piezo ignitor - Replace piezo ignitor.

  2.  Appliance produces unwanted odors.

a.  Appliance burning vapors from paint, hair spray, glues, etc. 

- Ventilate room. Stop using odor causing products while 

heater is running.

b.  Gas leak - Locate and correct all leaks.

  3.  Appliance shuts off during use. (Pilot and main burner are 

off.)

a.  Not enough fresh air is available for ODS/pilot to operate - 

Open window and/or door for ventilation.

b.  Low line pressure - Contact local gas company.

c.  ODS/pilot is partially clogged - Clean ODS/pilot.

d.  Defective thermocouple - Replace pilot.

  4.  Appliance shuts off during use. (Pilot stays on.)

a.  Low line pressure - Check line pressure to the valve.

b.  Defective  thermopile  -  Check  pilot  flame,  check  wire 

connections, output should be a minimum of 325 millivolts 

across TH/TP and TP terminals with ON/OFF switch off.

  5.  Gas odor even when control knob is in oFF position.

a.  Gas leak - Locate and correct all leaks.

b.  Control valve defective - Replace control valve.

  6.  When ignitor button is pressed, there is spark at oDS/pilot, 

but no ignition.

a.  Gas supply turned off or manual shutoff valve closed - Turn 

on gas supply or open manual shutoff valve.

b.  Control knob not in PILOT position - Turn control knob to 

PILOT position.

c.  Control knob not pressed in while in PILOT position - Press 

in control knob while in PILOT position.

d.  Air in gas lines when installed - Continue holding down control 

knob. Repeat igniting operation until air is removed.

e.  ODS/pilot is clogged - Replace ODS/pilot assembly or get 

it serviced.

f.  Gas regulator setting is not correct - Replace gas 

regulator. 

  7.  oDS/pilot lights but flame goes out when control knob is 

released.

a.  Control knob not fully pressed in - Press in control knob 

fully.

b.  Control knob not pressed in long enough - After ODS/pilot 

lights, keep control knob pressed in 30 seconds.

c.  Manual Shutoff valve not fully open - Fully open manual 

shutoff valve.

d.  Thermocouple connection loose at control valve - Hand 

tighten until snug, then tighten 1/4 turn more.

e.  Pilot  flame  not  touching  thermocouple,  which  allows 

thermocouple to cool, causing pilot flame to go out. This 

problem could be caused by either low gas pressure or dirty or 

partially clogged ODS/pilot - Contact local gas company. 

f.  Thermocouple damaged - Replace thermocouple.

g.  Control valve damaged - Replace control valve.

  8.  Burner does not light after oDS/pilot is lit.

a.  Burner orifice clogged - Clean burner or replace main burner 

orifice.

b.  Burner  orifice  diameter  is  too  small  -  Replace  burner 

orifice.

c.  Inlet  gas  pressure  is  too  low  -  Contact  qualified  service 

person. 

  9.  If burning at main burner orifice occurs (a loud, roaring 

blow torch noise).

a.  You must turn off burner assembly and contact a qualified 

service person.

b.  Manifold pressure is too low - Contact local gas company.

c.  Burner  orifice  clogged  -  Clean  burner  or  replace  burner 

orifice.

 10.  Logs appear to smoke after initial operation.

a.  Vapors from paint or curing process of logs - Problem will 

stop after a few hours of operation. Run the heater with the 

damper open if you have one, or open a window for the first 

few hours. 

  Log heater is intended to be smokeless. Turn OFF heater 

and call qualified service person.

 11.  Heater produces a whistling noise when main burner is 

lit.

a.  Turning control knob to HIGH position when main burner is 

cold - Turn control knob to LOW position and let warm up 

for a minute.

b.  Air in gas line - Operate burner until air is removed from 

line. Have gas line checked by local gas company.

c.  Dirty or partially clogged burner orifice - Clean burner or 

replace burner orifice.

 12.  No gas to pilot.

a.  LP-regulator shut down due to inlet pressure too high - 

Verify LP tank regulator is installed and set at 11" to 13" 

w.c. Replace regulator on heater.

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the 

heater.

TROUBLEShOOTINg

SyMpTOMS - pOSSIBLE CAUSES AND CORRECTIONS

Summary of Contents for VFP36PP32EN-2

Page 1: ...here not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Premium Vent Free Multi...

Page 2: ...6 Gas Line Connection 17 Placement of Glowing Embers and Lava Rock 18 Operation Instructions Flame Appearance 19 VFP36 SP PP 32 Lighting Instructions 20 Burner Instructions 21 Pilot Flame Characterist...

Page 3: ...kage See Figure Below Nailing Flange 10 x 1 2 Phillips Hex Head Screw 10 x 1 2 Phillips Truss Head Screw Romex Connector HARDWARE PACKAGE 10 X PHILLIPS HEX HEAD SCREW 16 10 X PHILLIPS HEX HEAD SCREW 2...

Page 4: ...avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do not place clothing or other flammable material on or near the appli...

Page 5: ...orm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls o...

Page 6: ...WARNING This appliance is equipped for natural gas or propane gas Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2...

Page 7: ...LSU24RR 2 Accessories EK 1 Embers Kit EK2 Embers Kit PE 20 Platinum Embers FBB5 Automatic Blower SCV 1 Speed COntrol Variable for use with FBB5 FRBC Battery Operated Remote Control FRBTC Battery Opera...

Page 8: ...nings gasketed or sealed and b Weather stripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door frames between sole...

Page 9: ...option 3 Figure 1 Each ventilation grill or opening shall have a minimum free area of one square inch per 1 000 BTUH of the total input rating of the gas equipment in the confined space Figure 1 Warni...

Page 10: ...Tubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the authority havingjurisdictionThestateofMassach...

Page 11: ...l should not be less than 1 3 4 See Figures 4a and 4b Combustible material clearance from front of firebox 36 minimum Fireplace Side and Back Clearances The fireplace outer casing side s require a min...

Page 12: ...CLEARANCE REQUIRED FROM TOP EDGE OF FIREPLACE Ceiling Clearances The ceiling height should not be less than 42 from the top of the hood See Figures 6a and 6b Mantel Clearances Vent free fireplace mode...

Page 13: ...end face A B C A B C Framing Peninsula Framing See Through Figure 9 In planning the installation for the fireplace it is necessary to determine where the unit is to be installed and whether optional...

Page 14: ...P36SP VFP36PP A 34 3 4 34 3 4 B 39 39 C 24 24 D 22 22 E 36 36 F 34 1 4 35 1 4 G 29 1 8 29 1 8 H 37 3 4 37 3 4 I 1 1 4 1 1 4 J 6 1 8 6 1 8 K 2 1 2 2 1 2 L 5 5 M 24 1 8 24 1 8 N 33 1 2 33 1 2 SEE THRU L...

Page 15: ...ming material Use at least one 1 nail or screw per bracket to secure in place IMPORTANT Check squareness of the fireplace prior to securing to framed opening See Figure 12 NOTICE On See Through models...

Page 16: ...ched as desired Attention Flush panels may not be used on these models INSTALLING HOODS Black hoods are furnished with each fireplace or the optional hood s and MUST be installed before the fireplace...

Page 17: ...onnector cannot exceed three feet in length Gas access holes are provided through the side panel s of the fireplace See Figure 14 Check gas type Use only the gas type indicated on the rating plate If...

Page 18: ...15 NOTICE Only the rockwool supplied with this unit or ordered in accordance with the Parts List on pages 30 and 31 should be used on this burner See the Parts List on pages 30 and 31 to order replace...

Page 19: ...various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the i...

Page 20: ...all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance...

Page 21: ...ting o NAT gas Air shutter 1 8 3 2 mm minimum open o LP gas Air shutter full open For best results when lighting the burner have your adjustable flame knob to the HI position then adjust to a lower se...

Page 22: ...in Figure 17 See Troubleshooting page 24 Cleaning and Pilot Maintenance Oxygen Depletion Sensor Pilot Figure 18 When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follow...

Page 23: ...liance place the remote receiver next to the gas valve Install remote control receiver behind bottom louver Refer to remote control installation and operating instructions for more details on remote c...

Page 24: ...ting is not correct Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed...

Page 25: ...emove the tab on the side of the receptacle hot side to split receptacle This will be required to separate blower and Accent Light circuits 2 Power for switched and live sides of Duplex Receptacle mus...

Page 26: ...ng be performed by a qualified electrician See Figures 20 and 21 1 If installed turn OFF gas supply to fireplace 2 If applicable turn OFF electric supply to fireplace 3 Remove bottom louver from firep...

Page 27: ...ation plug the power cord into the junc tion box receptacle previously installed in the bottom of the fireplace See Figure 23 9 Once all connections are made electrically it is recommended that you te...

Page 28: ...g can be plugged into the adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify pr...

Page 29: ...e gas valve Never obstruct the flow of the combustion and ventilation air Keep the front of the firebox clear of all obstacles and materials Screen panels must be in position while fireplace is in ope...

Page 30: ...ASSEMBLY UPPER END 11 N A N A 24058 24058 LOUVER ASSEMBLY LOWER END 12 20020 20020 20145 20145 HOOD 13 N A N A 24056 24056 HOOD PENINSULA 14 20143 20143 20143 20143 FRONT FRAME ASSEMBLY 15 N A N A 24...

Page 31: ...6 SWITCH REMOTE OFF ON 34 R2313 R2313 R2313 R2313 IGNITER PIEZO W BLACK 35 24148 24148 TUBING ASSEMBLY PILOT TO REGULATOR NAT ONLY 36 R7063 R7063 REGULATOR PILOT NAT ONLY 37 20116 20116 TUBING ASSEMBL...

Page 32: ...13 Page 32 SEE THROUGH FIREPLACE PARTS VIEW 1 4 6 5 16 8 9 12 14 4 5 6 8 12 14 9 7 3 2 24 25 20 17 18 31 41 40 21 23 29 33 30 19 22 34 28 26 Nat Gas 36 37 35 27 42 32 38 39 24 25 43 44 45 46 47 44 21...

Page 33: ...33 PENINSULA FIREPLACE PARTS VIEW 1 4 5 6 8 9 11 10 12 13 14 15 16 8 12 14 9 7 3 2 24 25 20 17 18 31 41 40 21 23 29 33 30 19 22 34 28 26 Nat Gas 36 37 35 27 42 32 38 39 24 LP BURNER 25 43 44 45 46 47...

Page 34: ...uminum Frame Kits Black Brass Stainless Steel or Hammered Pewter For use with See Through mod els VFP36SP32 SERIES ONLY Contact dealer for all available optional frame kits Bottom Trim Strip Available...

Page 35: ...onal hood acces sories Louvers Styles include Slat Mission Arch and Leaf Pat terns Available as optional kits in Black Brass Ham mered Pewter and Stainless Steel finishes Contact dealer for all avail...

Page 36: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Page 37: ...ick Liners are made from Ceramic Fiber for rich detail and lasting beauty Banded Brick Liners have dark creamed coffee bricks with charcoal mortar in running bond courses plus an accent band of diagon...

Page 38: ...OPEN END 3 8 COMBUSTIBLE CLEARANCE REQUIRED FROM TOP EDGE OF FIREBOX Clearances Combustible material clearance furniture parallel walls from front of fireplace 36 minimum Sidewall Clearances The clea...

Page 39: ...ng width assumes use of 1 2 wall board flush to the end face A B C A B C Framing Peninsula Framing See Through Web Site www empirecomfort com Premium Vent Free Fireplaces SEE THROUGH FIREPLACE MODELS...

Page 40: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: