OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS

Attention:

  It is recommended to install the blower assembly be

-

fore connecting gas inlet supply line.

Wiring

The  appliance,  when  installed,  must  be  electrically  grounded  in 

accordance  with  local  codes  or,  in  the  absence  of  local  codes, 

with the

 National Electrical Code, ANSI/NFPA 70

,  if  an  external 

electrical  source  is  utilized. 

This appliance is equipped with 

a three-prong [grounding] plug for your protection against 

shock hazard and should be plugged directly into a properly 

grounded three-prong receptacle. Do not cut or remove the 

grounding prong from this plug. 

For an ungrounded receptacle, 

an adapter, which has two prongs and a wire for grounding, can be 

purchased, plugged into the ungrounded receptacle and its wire 

connected to the receptacle mounting screw. With this wire com

-

pleting the ground, the appliance cord plug can be plugged into the 

adapter and be electrically grounded.

Caution: 

Label all wires prior to disconnection when servicing 

controls. Wiring errors can cause improper and dangerous op

-

eration. Verify proper operation after servicing.

NOTICE:

 

Junction box on right side of fireplace must be pre-wired 

at time of fireplace installation for use with blower assem

-

bly. A standard wall ON/OFF wall switch or optional SCV1 

Variable Speed Control Kit should be installed to activate 

power to the fireplace, and control the operation of the 

FBB5 Blower assembly. It is recommended that installa

-

tion of the wiring be performed by a qualified electrician. 

See Figure 20.

1.  If installed, turn OFF gas supply to firebox/gas log.

2.  If applicable, turn OFF electric supply to firebox.

 

CAUTION:

 all wiring should be done by a qualified electrician 

and shall be in compliance with all local, city and state build

-

ing  codes.  Before  making  the  electrical  connection,  make 

sure that main power supply is disconnected. The appliance, 

when installed, must be electrically grounded in accordance 

with local codes, with the national electrical code ansi/nfpa 70 

(latest edition).

Figure 20

A factory installed junction box is located on the lower right 

side of the fireplace. Wiring must be fed to the junction box 

and  attached  to  the  receptacle  that  is  provided.  From  right 

side of the fireplace, remove the screw securing the junction 

box assembly. Leave approximately 6” of wire in the junction 

box for connection.

Attach black wire to one side of the receptacle and white wire 

to opposite side of receptacle. The ground wire should be at

-

tached to the green (ground) screw.

Attention:

  If  installed,  do  not  damage  gas  inlet  supply  line 

when blower assembly is inserted into firebox. In some cases, 

removal the gas inlet supply line may be necessary. 

For Vent Free Fireboxes

1.  Determine which type of firebox you have prior to installation. 

See Figures 21 - 22.

Deluxe Premium Models (Flush / Louvered)

Figure 21

Select Firebox Models

Figure 22

Summary of Contents for VFP32FB Series

Page 1: ...nstallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency...

Page 2: ...NE CONNECTION 9 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 10 12 OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS 13 15 JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS 16 MAINTENANCE 16...

Page 3: ...f such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating...

Page 4: ...Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Framing and Finishing Combustible finishing materials requires 3 4 inch...

Page 5: ...the non combustible board supplied with the fireplace before adding paint tile or stone Attach tile or other non combustible products to the fireplace face and to the non combustible area Figures 29 a...

Page 6: ...alled directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you...

Page 7: ...2 Height from the bottom of the box to the upper gas line opening 8 4 8 4 8 4 8 4 8 4 8 4 L Depth from the front of the box to the gas line opening 15 7 15 7 15 7 15 7 15 7 15 7 M Depth from the rear...

Page 8: ...less steel or hammered pewter hoods are desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosely attach two screws...

Page 9: ...ane fireboxes to reduce the supply tank pressure to a maximum of 14 inch w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED PROPANE TANK CAN C...

Page 10: ...d prior to or at the time of firebox installation to framing The Fresh Air kit must be installed prior to the installation of wall board or other finishing materials around the unit Hardware needed no...

Page 11: ...ilding 2 Secure the 4 inch diameter duct to the Slide Assembly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exterior wall cutout 4 Fr...

Page 12: ...6 1217 Page 12 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer Hardware...

Page 13: ...should be installed to activate power to the fireplace and control the operation of the FBB5 Blower assembly It is recommended that installa tion of the wiring be performed by a qualified electrician...

Page 14: ...onnection A 6 The other fan control wire has a 1 4 male terminal Attach this terminal to the open terminal on the blower power cord See Figure 27 Connection B 9 Route the wires away from moving parts...

Page 15: ...t indi cates a dirty blower wheel Remove fan and clean blower wheels Blower Wiring See Figure 26 For Wiring WARNING Unplugging of blower accessory will not stop the heater from cycling To turn off gas...

Page 16: ...HE ELECTRICAL CONNECTION MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED THE APPLIANCE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WIT...

Page 17: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Page 18: ...BLOWER COVER PLATE 5 R7051 R7052 R7053 R7051 R7052 R7053 ROD SCREEN QUANTITY 2 6 20486 21087 33607 20486 21087 33607 HOOD 7 R9292 R9292 R9292 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293 R9293 R...

Page 19: ...33742 6 1217 Page 19 PARTS VIEW LOUVER FLUSH...

Page 20: ...V 1 Brick Liners Liner for Firebox Contact dealer for all available optional liner kits Fresh Air Kit Deluxe and Premium Fireboxes VFA2 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hammered...

Page 21: ...hes Contact dealer for all available optional louver accessories Bottom Trim Strip Available as optional kits in Brass Hammered Pewter and Stainless Steel finishes Contact dealer for all available opt...

Page 22: ...ctive workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated i...

Page 23: ...33742 6 1217 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 24: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Reviews: