![Empire Comfort Systems VFP30CA30BN-3 Owner'S Manual Download Page 15](http://html1.mh-extra.com/html/empire-comfort-systems/vfp30ca30bn-3/vfp30ca30bn-3_owners-manual_2403939015.webp)
26563-4-0111
Page 15
Figure 14 shows a correct main burner flame pattern. Figure 15
shows an incorrect main burner flame pattern.
If main burner flame pattern is incorrect, as shown in Figure 15:
• See Troubleshooting, pages 18 and 19.
Correct Main Burner Flame
Figure 14
Incorrect Main Burner Flame
Figure 15
Cleaning and Maintenance / Main Burner
WARNING
Turn off heater and let cool before cleaning.
After use, cleaning of the main burner may be required for the proper
flame. The main burner may be cleaned by applying air pressure
to the ports on the main burner.
Cleaning the Log Set and Firebox
CAUTION
Do not handle these logs with your bare hands. Always wear
gloves to prevent skin irritation.
During the annual inspection and maintenance appointment, the
service person should clean dust, lint, and any light accumulation
from the logs and the firebox area. An extra-soft brush should be
used on the logs and burner as they are extremely fragile; a vacuum
cleaner may be used on the firebox. If at any time the logs cannot
be removed or installed without forcing, the cause must be found.
The logs must never be forced.
CAUTION
The ceramic logs are durable when handled and installed properly.
However, they are delicate and may be damaged easily if not
handled with care. Handling damage to the ceramic logs is not
covered by warranty.
Do not HanDLe Logs WHiLe tHeY aRe Hot. aLLoW PLentY
oF tiMe FoR tHe aPPLiance to cooL coM-PLeteLY BeFoRe
HanDLing.
PLEASE NOTE
It is normal for appliances fabricated of steel to give off
some expansion and/or contraction noises during the start
up or cool down cycle. Similar noises are found with your
furnace heat exchanger or car engine.
MAIN BURNER FLAME ChARACTERISTICS
YELLOW FLAMES
BLUE FLAMES