39235-1-0219
Page 25
Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110
volts. Maximum length of 20 feet of 16 AWG to conductor wires is
to be used with all optional switches.
Use the two leads (Red and Green) to attach optional components.
check 750 Millivolt system operation
Millivolt system and all individual components may be checked with
a millivolt meter 0-1000 MV range.
Figure 24
MILLIVOLT CONTROL VALVE WIRING
Remote Receiver
Use the following steps to place the remote receiver adjacent to
the gas valve.
Attention:
The remote receiver bracket is not used in this
installation.
1. The remote receiver can not be placed behind the gas valve
and burner assembly.
2. When facing the appliance, the remote receiver must be placed
to the right of the gas valve.
Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for
more details on remote control.
THERMOCOUPLE
(PROPANE)