28040-3-0511
Page 31
7. With the MANUAL knob in
MAN
position a manual pi-
lot valve operator and piezo igniter are accessible.
Ignition with match:
Fully push down manual pilot valve operator and hold
in, to start pilot gas flow.
Immediately light the pilot with a match, while continuing to
hold in the manual pilot valve operator for about one (1) min
-
ute after the pilot is lit. Release manual pilot valve operator. If
pilot does not stay lit, wait five (5) minutes and repeat.
Ignition with piezo igniter:
Change the ignition cable from the receiver to the valve. Use
the push piezo igniter to ignite. If pilot does not stay lit, wait
five (5) minutes and repeat.
Caution
:
If the pilot does not stay lit after several tries, turn
the gas control knob (main valve knob) to
OFF
and proceed
to step 11.
8. If applicable, reinstall the top cover on the burner base before
proceeding.
9. Turn MANUAL knob to the
ON
, full counterclockwise
position.
10. Turn main valve knob to the full
ON
, full
counter-
clockwise position.
11. If the appliance will not operate, follow the instructions "TURN
OFF GAS TO APPLIANCE" and call the service technician or
gas supplier.
TURN OFF GAS TO AppLIANCE
•
Press OFF button on remote.
•
Follow appliance instructions for gaining accessibility to the
gas control.
•
Place ON/OFF switch in
O
(off position).
•
Turn main valve knob to the
OFF
full clockwise
position.
•
Replace appliance top cover.
MISCELLANEOUS
Low Battery Indication
Receiver:
three short beeps will sound when motor turns
Remote with display:
"BATT" will appear on display
Notice
:
Thermostatic Displays/Handsets: If the battery of the
handset is low or if the transmitter is out of the communi-
cation range, the motor turns down the valve to pilot gas
after 6 hours.
Notice
:
With very low battery the GV60 system shuts off the fire
completely. This will not happen if the power supply is
interrupted.
Battery replacement
Battery replacement is recommended at the beginning of each
heating season. Do not use metal tools to remove batteries. Using
a metal tool could cause a short that may damage the receiver.
Location of Receiver
When the RF-receiver is placed in the appliance, the surrounding
metal can reduce reception considerably. The position of th an-
tenna on the receiver also influences reception. It is recommended
to straighten the antenna. The antenna must not come in contact
or cross the ignition wire, this may render the receiver inoperable.
CAUTION:
Keep receiver free from debris and dirt. Protect
the receiver with a plastic bag until all construc-
tion is complete.
PIEZO IGNITER
ON/OFF SWITCH
IN
POSITION
ON
8 WIRE
RECEIVER JACK
MICROSWITCH
MAIN VALVE KNOB
IN
POSITION
OFF
MANUAL PILOT
VALVE OPERATOR MANUAL KNOB
IN
POSITION
MAN
CONNECTION
PIEZO IGNITER
TAB 2.8 X 0.8 mm
CUTOUT FOR
PILOT GAS
ADJUSTMENT
MANUAL KNOB
IN POSITION FOR
AUTOMATIC IGNITION
Figure 27
Figure 28
INTERMITTENT pILOT REMOTE ELECTRONIC IGNITION AND
CONTROL SYSTEM