The firebox is designed to accept a 3/8-inch gas line for an approved 

vent-free gas logset. Have the line installed by a qualified service 

person in accordance with all building codes. Consult local building 

codes to properly size the gas supply line leading to the 3/8-inch 

hook-up at the unit. The state of Massachusetts requires that a 

flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. 

See 

Figure 11

.  On    models  with  refractory  brick  panels  installed, 

carefully remove the knockout in the refractory brick panel using a 

large standard screwdriver and hammer. First, place screwdriver in 

groove next to plug and pry sideways to pop out main plug. Then 

remove the remaining concrete in hole with gentle tapping with ball 

peen hammer and/or screwdriver. A masonry drill and bit may also 

be used to create a clean hole for the gas line to pass through. 

See Figure 12.

When  installing  optional  ceramic  fiber  side  panels  into  firebox, 

lay panel on a flat surface. Remove the gas line knockout (round 

depression) in the appropriate side panel using a drill or utility knife.
After the brick panel knockout is removed, the firebox wrap may 

have a round metal knockout that must be removed also. Use a 

screwdriver to punch out the metal knockout.
Check gas type. Use only the gas type indicated on the gas log 

set rating plate. If the gas listed on the plate is not your type of gas 

supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator for all LP fireboxes to reduce the 

supply tank pressure to a maximum of 14 inch w.c. This is in addition 

to the regulator fitted to the log set.

WARNING: CONNECTION DIRECTLY TO AN UNREGULATED 
L.P. TANK CAN CAUSE EXPLOSION. 

Install only a ANSI Z21.11.2 vent-free log set into this firebox. 

Figure 11

Extended Hoods

If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will 
extend out 2" farther out into the room. Contact your local dealer for details.

Finishing

All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-

combustible material. 

Hearth extensions are recommended, but not required for these  fireboxes.

VB4H32BL

Standard Black

VB4H36BL

Standard Black

VB4H42BL

Standard Black

VB4H32BR

Polished Brass

VB4H36BR

Polished Brass

VB4H42BR

Polished Brass

VB4H32SS

Stainless Steel

VB4H36SS

Stainless Steel

VB4H42SS

Stainless Steel

VB4H32HP

Hammered Pewter

VB4H36HP

Hammered Pewter

VB4H42HP

Hammered Pewter

INSTALLING HOOD

GAS LINE CONNECTION

Brick Panel

Figure 12

GAS ACCESS HOLES

Summary of Contents for VFD32FB0F-3

Page 1: ...ET IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION ANSI Z21 91 Ventless Fireplace Enclosures for Gas Fired Decorative Type Unvented Room Heaters WARNING...

Page 2: ...NE CONNECTION 9 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 10 12 OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS 13 15 JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS 16 MAINTENANCE 16...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...dicular combustible side wall should not be less than 6 inches See Figure 1 Firebox Side and Back Clearances The firebox outer casing side and back flanges are zero clearance to combustibles Top Frami...

Page 5: ...talled it must meet the clearance requirements detailed below Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 inches Leave at least 36 inch...

Page 6: ...d directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you sho...

Page 7: ...8 F 31 36 40 31 36 40 G 22 1 4 24 1 4 24 1 4 22 1 4 24 1 4 24 1 4 H 6 1 8 6 1 8 6 1 8 1 3 16 1 3 16 1 3 16 I 28 3 8 30 3 8 30 3 8 28 3 8 30 3 8 30 3 8 J 8 5 16 8 5 16 8 5 16 8 5 16 8 5 16 8 5 16 K 4...

Page 8: ...ss stainless steel or hammered pewter hoods are desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two scr...

Page 9: ...ut that must be removed also Use a screwdriver to punch out the metal knockout Check gas type Use only the gas type indicated on the gas log set rating plate If the gas listed on the plate is not your...

Page 10: ...d the unit Hardware needed not provided 4 inch Aluminum Flex Duct 2 Band Clamps Tools needed Gloves Metal snips 5 16 inch Nut Driver Phillips Screwdriver Caution Sharp edges Slide Assembly Installatio...

Page 11: ...hood to the building 2 Secure the 4 inch diameter duct to the Slide Assembly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exterior wa...

Page 12: ...0 0314 Page 12 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer Hardware...

Page 13: ...w er to the Firebox and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 20 1 If installed turn OF...

Page 14: ...te the wires away from moving parts of the blower assem bly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord in...

Page 15: ...n blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn clockwise to OFF D...

Page 16: ...Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 inches of wire in the junction box for connection Attach black wire to one side of the receptacle and white wir...

Page 17: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 18: ...UANTITY 2 8 R10388 R10392 R10392 BRICK PANEL RIGHT REFRACTORY BRICK 8 31675 31678 31678 BRICK PANEL RIGHT FIBER BRICK 9 R10386 R10390 R10394 BRICK PANEL BACK REFRACTORY BRICK 9 31676 31679 31680 BRICK...

Page 19: ...33637 0 0314 Page 19 PARTS VIEW 1 2 5 4 3 6 10 9 8 7 12 12 16 11 13 14 15...

Page 20: ...1 Brick Liners Deluxe Firebox Contact dealer for all available optional liner kits Fresh Air Kit 1 2 3 Deluxe and Premium Fireboxes VFA2 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hammered...

Page 21: ...ss Steel finishes Contact dealer for all avail able optional louver acces sories Bottom Trim Strip Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for...

Page 22: ...tive workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in...

Page 23: ...33637 0 0314 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: