background image

Page 1

16934-3-0806

INSTALLATION INSTRUCTIONS 

AND 

OWNER'S MANUAL

INDOOR UNVENTED 

GAS FIREPLACE

MODEL

CHBR-16-3

EFFECTIVE DATE

AUGUST 2006

WATER  VAPOR:  A  BY-PRODUCT  OF 

UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An 

unvented room heater produces approximately one 

(1) ounce (30ml) of water for every 1,000 BTU's 

(.3KW's) of gas input per hour. Refer to page 6.

WARNING:  If  not  installed,  operated  and 

maintained in accordance with the manufacturer's 

instructions,  this  product  could  expose  you  to 

substances in fuel or from fuel combustion which 

can cause death or serious illness.

This is an unvented gas-fired heater. It uses air 

(oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventilation 

air must be provided. Refer to page 7.

This appliance may be installed in an aftermarket, 

permanently  located,  manufactured  (mobile) 

home, where not prohibited by local codes. 
This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases.

Indoor Chimenea

OUTFITTERS SERIES

Installer:  Leave this manual with the appli-

ance.

Consumer: Retain this manual for future refer-

ence.

—  Do  not  store  or  use  gasoline  or  other  flam-

mable  vapors  and  liquids  in  the  vicinity  of 

this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

—  Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

WARNING:  If  the  information  in  these  in-

structions  are  not  followed  exactly,  a  fire  or 

explosion  may  result  causing  property  dam-

age, personal injury or loss of life.

Summary of Contents for superb CHBR-16-3

Page 1: ...ted manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other...

Page 2: ...for Adequate Combustion and Ventilation Air 7 Clearances 8 Gas Supply 9 Set Up Instructions 10 Placement of Glowing Embers and Lava Rock 11 Operation Instructions Flame Appearance 12 Thermostat Opera...

Page 3: ...re and draperies Do not place clothing or other ammable material on or near the appliance Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid...

Page 4: ...lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Page 5: ...r future reference Please read this manual before installing and using the appliance Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installermustha...

Page 6: ...fore you get started Carefully inspect the contents for shipping damage If any parts are missing or damaged immediately inform the dealer from whom you purchased the appliance Do not attempt to instal...

Page 7: ...installed measure the length width and height of the area Example The area measures 16 feet in length 12 feet in width and 8 feet in height the area is 1 536 cubic feet The CHBR 16 can be installed in...

Page 8: ...Page 8 16934 3 0806 CLEARANCES CLEARANCES Minimum Clearances From Combustible Construction Figures 2 and 3 Side 2 Rear 2 Top 24 Floor Combustible Figure 1 Figure 2...

Page 9: ...s capped on the bottom in which condensation and foreign particles may collect Figure 3 The use of the following gas connectors is recommended ANSZ21 24ApplianceConnectorsofCorrugatedMetalTubing and F...

Page 10: ...tion where it will t through the front door opening Guide the gas valve through the large hole in the bottom of the body casting The burner support plate will come to rest on the three at mounting tab...

Page 11: ...ddle logs Rock wool should not be placed in the area of the pilot assembly Replacement of loose material glowing embers must be purchased from Empire Comfort Systems Inc Application of excess loose ma...

Page 12: ...n to light maintain the standing pilot Low Minimum gas rate pleasing yellow ames glowing embers High Maximum gas rate pleasing yellow ames glowing embers Generator Ignition Piezo Ignitor allows lighti...

Page 13: ...ent to lowest setting If applicable Turn off all electric power to the heater Note For easy access to valve for lighting pilot remove branch log and middle log from burner assembly before lighting 1 S...

Page 14: ...ame Figure 8 If pilot ame pattern is incorrect as shown in Figure 8 See Troubleshooting page 17 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot Figure 9 When the pilot has a large yellow...

Page 15: ...hole Remove lint or particles with brush Failure to keep air intake hole clean will result in sooting and poor combustion ANNUALCLEANING INSPECTION Refer to parts diagram for location of items discus...

Page 16: ...te Receiver Figure 10 1 The remote receiver can be placed behind the gas valve on under side of chimenea 2 Attach remote receiver to the at bottom of casing behind gas valve on underside of chimenea R...

Page 17: ...mbly or have it serviced g Gas regulator setting is not correct Replace gas regulator 7 ODS pilot lights but ame goes out when control knob is released a Control knob not fully pressed in Press in con...

Page 18: ...STING ASSEMBLY GREEN INCLUDES STACK CASTING R 6476 KNOB GREEN R 6474 CAP GREEN 2 R 6641 MOUNTING RING RED 2 R 6642 MOUNTING RING GREEN 3 R 6479 CHIMENEA BODY CASTING ASSEMBLY RED INCLUDES BODY CASTING...

Page 19: ...Page 19 16934 3 0806 PARTS VIEW...

Page 20: ...20 16934 3 0806 SERVICE NOTES Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort...

Reviews: