39010-0-1018
Page 4
Ceiling Clearances:
The ceiling height should not be less than
84 inches from the bottom of the firebox.
See Figure 4.
Mantel Clearances:
Vent free firebox models must use the
hood supplied with the firebox, or one of the optional hood kits
available for each model. If a combustible mantel is installed, it
must meet the clearance requirements detailed below.
Leave at least 36 inches clearance from the front of the firebox.
Figure 4 - Clearances to Combustibles
CLEARANCES
Sidewall Clearances:
The clearance from the inside of the firebox
to perpendicular combustible side wall should not be less than 6
inches.
See Figure 1.
Firebox Side and Back Clearances:
The firebox outer casing side
and back flanges are zero clearance to combustibles.
Top Framing and Finishing:
Combustible finishing materials
requires 3/4 inch to top of unit. There are two shoulder bolts attached
to the unit to maintain the minimum clearance.
See Figures 2 and 3
.
Figure 1
Figure 2 - Louvered Models
Figure 3 - Flush Models