background image

28096-23-1016

Page 14

Pilot Flame Pattern (Figure 4)

Figure 4 shows a correct pilot flame pattern. The correct flame will 

be blue and will extend beyond the thermopile. The flame will sur

-

round the thermopile just below the tip. A slight yellow flame may 

occur where the pilot flame and main burner flame meet. 

After use, cleaning of the pilot burner may be required for the proper 

flame. The pilot orifice can be cleaned with high pressure air or 

by placing under running water. Pilot orifice must be dry before 

replacement. Use a pipe cleaner to clean inside the pilot after the 

pilot orifice has been removed.

To Remove Pilot orifice

1.  Disconnect the pilot supply line at the pilot burner.

2.  Remove pilot orifice from pilot burner. It may be necessary to 

tap on pilot burner in order to remove the pilot orifice.

Pilot Flame Pattern

Figure 4

If pilot flame pattern is incorrect

•  See Troubleshooting, page 17.

Main Burner Flame Pattern

The main burner flame will be completely yellow. 

Main Burner Flame Ignition and extinction

When the main burner is ignited it will take a few seconds for the 

full flame pattern to develop.
When the main burner is extinguished it will take a few seconds for 

the flames to disappear. 

PIlot and MaIn Burner FlaMe cHaracterIstIcs

Keep the control compartment, logs and burner area surrounding 

the logs clean.

ThE  LoGS  CAn  GET  vERY  hoT—  hAnDLE  onLY  WhEn 

cool.

Always keep the appliance area clear and free from combustible 

materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the 

front of the appliance clear of all obstacles and materials.

cleaning Instructions

This appliance is built using mostly high-grade stainless steel to 

resist rust-through. In outdoor applications, all stainless steel will 

develop a dull patina and, depending on the local environment 

cleanInG and serVIcInG

and on the materials used in the installation, may develop some 

surface oxidation (rust). This does not affect the performance of 

the fireplace, and does not require any action to correct. If you 

prefer keeping your fireplace front looking factory-fresh, clean it as 

required with stainless steel cleaner.

When installation application includes highly acidic applications 

such as mortar or stone etching, do not remove the protective 

PVC film from the stainless steel until after this application is com

-

plete. Once the film has been removed we recommend that the 

appliance be cleaned with a stainless steel cleaner immediately.

Please note that areas where the film has been formed (corners, 

hems, etc.) may require  extra cleaning  due  to the properties  of 

the film. Ensure that all protective film has been removed from the 

fireplace prior to burning the appliance.  

Summary of Contents for ONI-24-2

Page 1: ...in the vicinity of this or any other appliance DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this app...

Page 2: ...stics 14 Cleaning and Servicing 14 ONR 24 30 Wiring 15 Remote Control Installation and Operation 16 Troubleshooting 17 Parts View List 18 Master Parts Distributor List 19 How Tor Order Repair Parts 19...

Page 3: ...hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Addresses...

Page 4: ...in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may strati...

Page 5: ...ed Porch Installation The fireplace may be installed safely and is design certified by CSA to be installed in a screen porch with the following guidelines Minimum Porch Area 96 sq feet 9 sq m Minimum...

Page 6: ...inches water column 10 for LP and 3 5 for NAT For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator the appliance and its individual shutoff valve must be...

Page 7: ...ed for the minimum front opening of the firebox Follow these instructions to ensure safe installation Failure to follow instructions exactly can create a fire hazard CLEARANCES 2 Ventilation opening s...

Page 8: ...lity for proper orifice size identification For Canadian high altitude applications this appliance is suitable for installation at elevations between 0 feet 0m and 4 500 1 370m without change When ins...

Page 9: ...by the authority havingjurisdiction ThestateofMassachusettsrequiresthataflexible appliance connector cannot exceed three feet in length Figure 2 Pressure Testing of the Gas Supply System 1 To check t...

Page 10: ...nd will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft b...

Page 11: ...art has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING...

Page 12: ...CONTROL VALVE ELECTRONIC CONTROL MODULE AF 4000 B P RED BLACK BLACK BROWN RED ORANGE N A CUSTOMER PROVIDED WALL SWITCH CONTROL MODULE SHIELD GROMMETS SECURE SHIELD TO VALVE WITH TWO SCREWS ELECTRONIC...

Page 13: ...A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next...

Page 14: ...ontrol compartment logs and burner area surrounding the logs clean The logs can get very hoT Handle only when cool Always keep the appliance area clear and free from combustible materials gasoline and...

Page 15: ...valve regulator controls the burner pressure which should be checked at the pressure test point Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test poi...

Page 16: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 17: ...wires may be grounded Remove wall switch wires from valve terminals if pilot now stays lit trace wall switch wiring for ground May be grounded to appliance or gas supply Check thermopile with millivol...

Page 18: ...e 6 27932 27932 27932 27932 Burner Support Welded Assembly Right 8 R10810 R10810 R10408 R10408 Valve LP 8 R12005 R12005 R10407 R10407 Valve NAT 9 28393 28393 Piezo Bracket 10 R9761 R9761 Piezo 11 3503...

Page 19: ...n be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number a...

Page 20: ...nce for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and from...