43115-2-0821
43115-2-0821
Page 34
7. Remove outside mounting plate with tube attached from wall.
Mark and cut the extra length of the 6 5/8” (168 mm) diameter
tube from the opposite end. Do not crimp or enlarge tube.
8. Attach the 4” (102 mm) diameter flue outlet tube onto the rigid
venting system or directly to fireplace. Ensure the 4” (102 mm)
diameter flue outlet tube is placed as far as possible onto the
rigid venting system. Mark the 4” (102 mm) diameter flue outlet
tube 2 1/2” (64 mm) beyond the vinyl siding kit or wall. See
Figure 53.
Remove the 4” (102 mm) diameter flue outlet tube
from rigid venting system. When installing directly to fireplace,
tape gasket needs to be used.
9. Mark or wrap tape completely around the tubes at the marked
points to help in making a true cut. Do not crimp or enlarge
tubes.
10. From outside: Push the 6 5/8” (168 mm) diameter inlet tube/
mounting plate onto end of rigid venting system to correct posi-
tion. Fasten the outside mounting plate to the vinyl siding kit or
wall with four 10 x 1 1/2” screws. (Ensure upward slope).
11. From inside: Attach the inlet tube to the collar on the back of the
fireplace (or the rigid venting system) using three self tapping
screws.
12. Seal the 4” (102 mm) diameter flue outlet tube. Follow instruc
-
tions and diagram.
See Figure 54.
13. Fasten 4” (102 mm) diameter flue outlet tube in place. Do not
“twist” the flue outlet tube into the fireplace collar (or rigid vent
-
ing system). Hold the tube by the seam and push in using a
perpendicular “rocking” motion. This ensures the seam on the
tube stay intact.
14. Fasten vent cap end using three 10 x 1/2” screws to mounting
plate.
Sealing 4” (102 mm) Diameter Flue Outlet Tube
Figure 52
Figure 53
Figure 54
NOTICE:
Tape gasket to be applied prior to installing to fireplace
flue outlet tube only. Tape gasket should not be used when mating
the flue outlet tube to a rigid venting system.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (CONT’D)
Summary of Contents for MILLIVOLT DVD32FP30N-3
Page 21: ...Page 21 43115 2 0821 Figure 31 EXAMPLES TOP VENT RUN Figure 30 Figure 29...
Page 41: ...Page 41 43115 2 0821 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES Figure 61...
Page 47: ...Page 47 43115 2 0821 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Page 48: ...43115 2 0821 Page 48 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...