background image

29847-5-0719

Page 1

Empire Comfort Systems Inc. • Belleville, IL

Attention: 

Install blower assembly before connecting gas 

inlet supply line

note:

 Junction box on right side of fireplace must be pre-

wired  at  time  of  fireplace  installation  for  use  with  blower 

assembly. It is recommended that an ON/OFF wall switch be 

installed by a qualified electrician that will activate the power 

supply to the fireplace.

Wiring

The appliance, when installed, must be electrically grounded 

in accordance with local codes or, in the absence of local 

codes, with the 

National Electrical Code, ANSI/NFPA 70

, if 

an external electrical source is utilized. 

this appliance is 

equipped with a three-prong [grounding] plug for your 

protection against shock hazard and should be plugged 

directly into a properly grounded three-prong receptacle. 

Do not cut or remove the grounding prong from this plug. 

For an ungrounded receptacle, an adapter, which has two 

prongs and a wire for grounding, can be purchased, plugged 

into the ungrounded receptacle and its wire connected to 

the receptacle mounting screw. With this wire completing 

the ground, the appliance cord plug can be plugged into the 

adapter and be electrically grounded. 

CAUtion

Label all wires prior to disconnection when servicing 

controls. Wiring errors can cause improper and dangerous 

operation. Verify proper operation after servicing.

BLoWer Motor

The blower motor does not have oiling holes. Do not attempt 

to oil the blower motor.

BLoWer WheeLs

The blower wheels will collect lint and could require periodic 

cleaning.  If  the  air  output  decreases  or  the  noise  level 

increases, it indicates a dirty blower wheel. Remove blower 

and clean blower wheels.

WArning

Unplugging of blower accessory will not stop the heater 

from cycling. to turn off gas to the heater (millivolt model): 

push in gas control knob slightly and turn clockwise to 

“oFF.” Do not force. to turn off gas on direct ignition 

model, turn gas line valve to “oFF.”

BLoWer instALLAtion

WArning

if previously installed, do not damage gas inlet supply 

line when blower assembly is inserted into fireplace. 

if necessary, removal of the gas inlet supply line may 

be necessary.

1.  Remove decorative front, valve cover (three screws), and 

glass door assembly.

2.  Reposition the extension module mount plate, module, and 

extension module by placing them in front of the valve.

3.  Insert the blower assembly past the firebox support leg 

with the motor portion angled to the front of the fireplace. 

see Figure 1

. Slide the blower past the supply tubing to 

position the blower along the back wall of the fireplace 

back in the open space along the left side of the fireplace.  

see Figure 2.

Figure 1

Figure 2

FBB9-1 BLoWer Kit

instALLAtion instrUCtions

instrUCtions MUst Be LeFt With the oWner For FUtUre reFerenCe AFter instALLAtion.