INSTALLATION
Flush Wall Installation
Figure 15
Combustible Surround Installation
Figure 16
Note:
For mantelshelf requirements,
see Figure 5
on page 10.
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated exterior
wall, it is recommended that the outer walls be insulated to
conform to applicable insulation codes.
Vent Runs
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four corner supports. (Example: Four concrete masonry blocks.)
These supports must be positioned so they contact all four
perimeter edges on the bottom of the unit (if allowed by local
codes).
NOTICE:
Discard insulation and retainer when venting from
the top of the fireplace.
TOP, 90° ELBOW WITH HORIZONTAL TERMINATION
Figure 17