38714-5-0920
Page 14
REAR VENT CONVERSION
Converting flue take-off to rear venting
When switching out the flue and inlet vent collars to run horizontally
off the rear vent, the following steps must be taken.
1. Remove the inlet vent collar (8 screws) and flue collar (4 screws)
from the top of the fireplace, and set to the side.
2. Remove the inlet cover plate (4 screws) and flue cover plate
(4 screws) located on the back of the fireplace. These will be
used to close the top flue and inlet openings.
3. Install flue cover plate over the top flue opening with 4 screws.
4. Reinstall the inlet cover plate over the top inlet opening with 4
screws. See Figure 11.
5. Install the flue collar assembly to the rear flue with 4 screws.
6. Install the inlet vent collar to the rear of the fireplace with 8
screws.
7. This completes the conversion for a rear vent application.
SPECIAL VENT SYSTEMS
The following vent systems are acceptable for use with the DVP36(SP,PP) series fireplaces:
•
Simpson Duravent® PRO Series 4" - 6 ⅝"
•
Selkirk Direct-Temp® 4" - 6 ⅝"
•
Metal-Fab Sureseal® 4" - 6 1/2" (Note: Adapter pipe starter required)
•
Empire Horizontal Round Termination Kit DVVK-4RE, refer to page 39.
•
Empire Horizontal Round Termination Kit DVVK-4FRE
•
Empire Horizontal Round Termination Kit DVVK-4REVS
•
Empire Horizontal Round Flex Termination Kit DVVK-4FREVS
•
Empire Flexvent Kit DVVK-4F, refer to page 42.
•
Empire Flexvent Kit DVVK-4FV Vertical Flex Vent Kit, refer to page 23.
INLET VENT COLLAR
INLET VENT COLLAR
FLUE OUTLET COLLAR
FLUE OUTLET COLLAR
INLET VENT
COVER PLATE
INLET VENT
COVER PLATE
FLUE COVER PLATE
(See note above.)
FLUE COVER PLATE
VERTICAL VENTING
HORIZONTAL VENTING
Note: It is recommended that the
flue cover plate tab be pulled
outward prior to removal.
This will ensure that the plate
is not accidentally dropped
inside the rear air chamber.
Figure 11