26408-0-1009
Page 8
Mantel Chart (Figure 3)
Figure 3
Clearances (Figure 4)
Clearance from top of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 4
Figure 5
Note:** Island (C) and Room Divider
(D) installation is possible as long as the
horizontal portion of the vent system (H)
does not exceed 20 feet with a minimum
vertical run of 8 feet. See details in
Venting Section.
*When you install your Direct Vent
Fireplace in (D) Room divider or (E) Flat
on wall corner positions, a minimum of
6 inches clearance must be maintained
from the perpendicular wall and the front
edge of the appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Note:
Empire "Standard Mantels" are not approved for use with
the DVP36DP(31,71,91)(N,P) Series fireplaces.
CABINET
INSTALLATION
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
ISLAND
INSTALLATION
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NON-COMBUSTIBLE
FIRST 3 (SEE MAGNIFFIED
VIEW)
”
NAILING
FLANGES
GLASS FRONT
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
3"
CLEARANCES
LOCATING FIREpLACE
36”
(914mm)
6” (152mm)