VENT SYSTEM IDENTIFICATION
Figure 1
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE:
Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to
the “Special Vent Systems” section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use
Figure 22
on page 17 for top venting, or
Figure 35
on page
22 for rear venting to eliminate issues after installation. Check pipe
diameter on vent system and fireplace to verify the size is the same.
NOTICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
SPECIAL VENTING COMPONENTS (SIMPSON DURAVENT)
See Empire Comfort Systems Retail Price List for Simpson
Duravent part numbers and pricing.
Special DV Vent kits available from Empire Comfort Systems,
Inc. dealers.
DVVk-4VP Direct-Vent Fireplace Vent kit - Vertical, Includes
SD46DVa-VCH, SD46DVa-F6 and SD46DVa-SC
DVVk-4RE Direct-Vent Fireplace Vent kit, Thru-the-wall, for
5 to 13-3/4 inch wall thickness
DVVk-4TP
Direct-Vent Fireplace Vent kit for Top Vent, Thru-
the-wall, 8 to 11 inch wall thickness, Includes
SD46DVa-HC, SD46DVa-E90,
SD46DVa-09, SD46DVa-08a and SD46DVaWT
DVVk-4TSP
Direct-Vent Fireplace Vent kit for Top Vent, Thru-
the-wall, 5 to 7 inch wall thickness, Includes
SD46DVa-HC, SD46DVa-E90,
SD46DVa-06 and SD46DVa-WT
DVVk-5RP
Direct-Vent Fireplace Vent kit for Rear Vent, 6 to
12 inch wall thickness, Includes SD-58DVa06,
SD-58DVaHC, and SD58DVaWTEC
DVVk-5TP
Direct-Vent Fireplace Vent kit for Top Vent, Thru-
the-wall, 4 to 6 inch wall thickness, Includes
SD58DVaE90, SD58DVaHC,
SD58DVa06, and SD58DVaWTEC
DVVk-5VP Direct Vent Fireplace Vent kit - Vertical, Includes
SD58DVaVCH, SD58DVaSC, and SD58DVaF6
DVVk-5F
Horizontal Flex Vent Kit (4’ Flex) (1.22m)
NOTE:
all DVVk-4 Vent kits require use of the DVa47 adaptor.
*NOTE:
If using three 90° elbows during horizontal
termination, see
Figure 30.
Summary of Contents for DVP FP3 4 Series
Page 20: ...39359 0 1018 Page 20 Figure 30 Figure 31 EXAMPLES TOP VENT RUN Figure 29...
Page 45: ...39359 0 1018 Page 45 5 Log assembly is completed LOG PLACEMENT DVP 42 48...
Page 48: ...39359 0 1018 Page 48 Figure 74 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Page 56: ...39359 0 1018 Page 56 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...