INTRODUCTION
Warranty Information
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown
on the rating plate is the responsibility of the person and
company making the change.
The warranty will be voided by, and the warranter disclaims any
responsibility for the following actions:
•
Installation of any damaged fireplace insert or vent system
component.
•
Modification of the fireplace insert or direct vent system.
•
Installation other than as instructed by Empire Comfort
Systems, Inc.
•
Improper positioning of the logs or glass door assembly.
•
Installation and/or use of any component part not
manufactured or approved by manufacturer.
•
This appliance comes standard with a 120 V/AC cord
assembly to accommodate the blower accessory. An outlet
box may be installed in a bottom back corner of the existing
solid fuel masonry or factory built fireplace to plug in the cord
assembly, or the supplied power cord may be routed out
onto the hearth to a nearby outlet.
•
A 120 V/AC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
•
Low voltage and 120 V/AC cannot be shared within the
same wall box.
•
Once the appliance installation is completed, the installer
should check that control compartment wiring is secured in
a manner as to not interfere with blower, door latches, valve
controls, or the barrier assembly.