Kasap Tip Dik Buzdolapları 

 
 
 

 

 

 

 

 

OPERATION 

*Control Panel; 

 

 

 

 

 

 

 

A

 : Down Arrow Button 

 

 

 

 

 

 

 

B

 : Up Arrow Button 

 

 

 

 

 

 

 

C

 : Digital Screen 

 

 

 

 

 

 

 

D

 :Program Setting Button 

 

 

 

 

 

 

 

E

 : Menu Button 

 

 

 

 

 

 

 

F

 : ON/OFF  Button 

 
 
 
 
 
 

*Operating; 
 

 

Be sure that the inside of the trolley is clean and the trolley is constant to where it is  
before starting any process. 

 

Plug in the appliance. 

 

Switch to ON position. 

 

After Indicator lamps signal,inside temperature will be shown. 

 

For temperature setting;press set button of upper indicator.Temperature that is adjusted 
before will be seen on the screen. 

 

With direct buttons (

) set the desired temperature. 

 

Press Set button again. 

 

Inner temperature will be seen on the screen again.It means adjusted temperature was 
saved to memory. 

 

You can fill the banquet trolley during cooling process..In this situation cooling time will be 
a little bit longer. 

 

After Cooling Starts ; 

  Switch to OFF position. All lamps will be off. 

 

Unplug it and leave the plug on the trolley. 

 
 
 
 

Summary of Contents for EMP.BQ1-S

Page 1: ...T DESCRIPTION Page 3 A2 TECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 4 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G SPARE PART LIST EXPLODING DRAWING Page 9 H ELECTRIC CIRCUIT SCHEMA Page 17 ...

Page 2: ... disobeying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn off the...

Page 3: ... BQ3 S 720x885x1250 80 720x900x1370 EMP BQ4 S 505x775x1830 105 580x760x1760 A2 TECHNICAL INFORMATION Product Code Operatin g Temparat ure ºC Capacity Powe r KW Operat Volt V Isolation type Cooler Gas Cable mm EMP BQ1 S 0 5 Tropical 43 11xGN2 1 0 35 220 230 40 kg m polyurethane R 134 A 3x2 5 EMP BQ2 S 0 5 Tropical 43 2x 11xGN2 1 0 7 220 230 40 kg m polyurethane R 134 A 3x2 5 EMP BQ3 S 0 5 Tropical ...

Page 4: ...roduct to straight and sturdy ground please take necessary steps against possibility of overturn Technician who will serve for installation and service for the appliance must be professional on this subject and must have installation and service licenses by the company Connection to Electric Power Supply must be done by authorized person Please be sure that the voltage connected to appliance must ...

Page 5: ...city Do not attempt to use the appliance without suitable protective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Never use water to extinguish the fire All the damages because of not having earthing connection will not be on warranty Get the necessary cautions ...

Page 6: ...cator lamps signal inside temperature will be shown For temperature setting press set button of upper indicator Temperature that is adjusted before will be seen on the screen With direct buttons set the desired temperature Press Set button again Inner temperature will be seen on the screen again It means adjusted temperature was saved to memory You can fill the banquet trolley during cooling proce...

Page 7: ... then dry Do not use abrasive cleaning chemicals as these can leave harmful residues Do not clean the appliance by spraying water directly otherwise electric motor may get damaged PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person Get the periodic maintenance of the appliance once in every 15 days Check the wheels electric connections fan control system door and door ...

Page 8: ...e appliance doesn t cool THE APPLIANCE STOPPED 1 The appliance can stop due to low voltage In this situation check the voltage 2 If there is any load on banquet trolley the appliance may stop THE BRAKES CAN NOT BE APPLIED 1 Brakes and Wheels may have error In this situation inform the service DOOR IS NOT CLOSED 1 The banquet trolley may be overloaded 2 Door lock may have error If cooling is not do...

Page 9: ...9 COLD BANQUET TROLLEY Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP BQ1 S ...

Page 10: ...E Y EMP BQ1 S 008 9 DIGITAL THERMOSTAT Y EMP BQ1 S 009 10 BUTTON ON OFF Y EMP BQ1 S 010 11 CONDANSER Y EMP BQ1 S 011 12 FAN WING Y EMP BQ1 S 012 13 FAN CIRCLE PLASTIC Y EMP BQ1 S 013 14 FAN MOTOR Y EMP BQ1 S 014 15 DRAYER Y EMP BQ1 S 015 16 MOTOR Y EMP BQ1 S 016 17 PROBE Y EMP BQ1 S 017 18 INNER FAN Y EMP BQ1 S 018 19 LONG GASKET LATH Y EMP BQ1 S 019 20 SHORT GASKET LATH Y EMP BQ1 S 020 21 PLUG BE...

Page 11: ...11 COLD BANQUET TROLLEY Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP BQ2 S ...

Page 12: ...E Y EMP BQ2 S 008 9 DIGITAL THERMOSTAT Y EMP BQ2 S 009 10 BUTTON ON OFF Y EMP BQ2 S 010 11 CONDANSER Y EMP BQ2 S 011 12 FAN WING Y EMP BQ2 S 012 13 FAN CIRCLE PLASTIC Y EMP BQ2 S 013 14 FAN MOTOR Y EMP BQ2 S 014 15 DRAYER Y EMP BQ2 S 015 16 MOTOR Y EMP BQ2 S 016 17 PROBE Y EMP BQ2 S 017 18 INNER FAN Y EMP BQ2 S 018 19 LONG GASKET LATH Y EMP BQ2 S 019 20 SHORT GASKET LATH Y EMP BQ2 S 020 21 PLUG BE...

Page 13: ...13 COLD BANQUET TROLLEY Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP BQ3 S ...

Page 14: ...E Y EMP BQ3 S 008 9 DIGITAL THERMOSTAT Y EMP BQ3 S 009 10 BUTTON ON OFF Y EMP BQ3 S 010 11 CONDANSER Y EMP BQ3 S 011 12 FAN WING Y EMP BQ3 S 012 13 FAN CIRCLE PLASTIC Y EMP BQ3 S 013 14 FAN MOTOR Y EMP BQ3 S 014 15 DRAYER Y EMP BQ3 S 015 16 MOTOR Y EMP BQ3 S 016 17 PROBE Y EMP BQ3 S 017 18 INNER FAN Y EMP BQ3 S 018 19 LONG GASKET LATH Y EMP BQ3 S 019 20 SHORT GASKET LATH Y EMP BQ3 S 020 21 PLUG BE...

Page 15: ...15 COLD BANQUET TROLLEY Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP BQ4 S ...

Page 16: ...E Y EMP BQ4 S 008 9 DIGITAL THERMOSTAT Y EMP BQ4 S 009 10 BUTTON ON OFF Y EMP BQ4 S 010 11 CONDANSER Y EMP BQ4 S 011 12 FAN WING Y EMP BQ4 S 012 13 FAN CIRCLE PLASTIC Y EMP BQ4 S 013 14 FAN MOTOR Y EMP BQ4 S 014 15 DRAYER Y EMP BQ4 S 015 16 MOTOR Y EMP BQ4 S 016 17 PROBE Y EMP BQ4 S 017 18 INNER FAN Y EMP BQ4 S 018 19 LONG GASKET LATH Y EMP BQ4 S 019 20 SHORT GASKET LATH Y EMP BQ4 S 020 21 PLUG BE...

Page 17: ...17 COLD BANQUET TROLLEY Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA EMP BQ1 S BQ3 BQ4 I A1 M1 M2 Terminal Large lighted 0 1 Switch Compressor and Condenser Fan Inner air circulation fan ...

Page 18: ...18 COLD BANQUET TROLLEY Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA EMP BQ2 S I A1 M1 M2 Terminal Large lighted 0 1 Switch Compressor and Condenser Fan Inner air circulation fan ...

Reviews: