CONNECT GAS LINE FROM GAS PRESSURE REGULATOR TO GAS SUPPLY:
1.
Apply pipe-joint compound made for use with LP gas to the tapered (NPT)
threads of both adapters
d
supplied with gas line kit.
2.
Attach one adapter to the gas pressure regulator and the other to the gas
NOTE:
Do Not rotate the gas pressure regulator.
3.
c
to adapters
d
, one adapter at each end.
IMPORTANT:
All connections must be wrench tightened (requires two 10"
adjustable wrenches). Do not over-tighten the connections to the gas pressure
regulator. Overtightening may crack the regulator creating a leak.
b
c
e
a
d
d
a
Adapter (provided)
b
Gas Pressure Regulator
c
Gas Supply Line
d
Adapters (From Gas
Supply Line Kit)
e
COMPLETE CONNECTION
1.
handle is parallel to the gas pipe.
2.
Test all connections by brushing on an approved noncorrosive leak-detection
solution. If bubbles appear, a leak is indicated. Correct any leak found.
23