10" 1/16
(255.8 mm)
=
=
20" 35/64
(522 mm)
20" 5/16
(515.5 mm)
minimum
1" 1/4
(31.8 mm)
minimum
7" 7/8
(200 mm)
=
=
22.64
"
(575 mm)
minimum
cut-out depth
minimum height from the floor
22" 5/8
(574.4 mm)
cut-out height
23.42
"
(595 mm)
cut-out width
22.24
"
(565 mm)
Fig. 5.3
Fig. 5.4
Provide a hole for
gas connection to
1/2” diameter pipe
fitting.
Provide hole
for electrical
connection in
this area
Area for
electrical
connection
Gas line opening:
Provide a suitable hole on the bottom
of cutout. The centre of hole shall be
10” 1/16 (255.8 mm) from the centre of
cutout to the left side and 20” 35/64 (522
mm) from the front corner of cutout to
the back.
Grounded outlet:
The electric cord with 3-prong ground
plug has a length of 48” (1220 mm).
Grounded outlet should be located in an
area 7” 7/8 (200 mm) below the bottom
of cutout and only on the right side of the
cabinet (from the centre to the right side
of the cabinet).
A suitable hole has to be provided on
the bottom of the cutout, in an area
positioned on the right rear corner (1”
1/4 [31.8 mm] maximum from the right
side of cutout and from the rear corner
to maximum 20” 5/16 (515.5 mm) from
the front corner of cutout), to pass the
appliance cable.
5