8 Product Maintenance

Always disconnect the product from the power grid  and  wiring before performing any
maintenance of the product. If you have to enter places with a risk of fall, pay attention to
your safety.

Use only dry cloth to clean the product and do not use any liquid agents.
Coaxial   cables   installed   outdoors   should   be   replaced   once   in   a   few   years.  Unscrew   all   F
connectors and clean connector contacts, resp. shorten the coaxial cable by approx. 2 cm,  every 2
years.

Check the state of power supply and its mains cord periodically. If the mains cord or the
mains   plug   of   product   is   damaged,   it   must   be   replaced   by   manufacturer   or   qualified
technician to prevent any dangerous situation. Let the product serviced if the housing of
power supply is damaged.

If not used for long time, disconnect the product from the power grid.

9 Troubleshooting

Always disconnect the product from the power grid before working on product, otherwise
you risk the electric hazard. Pay attention to your safety if you have to enter places with a
risk of fall.

In the case the product does not work and LED of power supply is on:

Check   if   the   terrestrial   and   satellite   antennas   are   correctly  fixed,   optimally  set   and
connected to the product, satellite and terrestrial receivers turned on, plugged on and
correctly set.

Check   the   connector   connections.  The   inner   conductor   of  coaxial   cable   must   be   in
contact with the inner conductor of F socket and the shielding of coaxial cable with F
connector. Replace broken or interrupted coaxial cable.

Sometimes the reset of the multiswitch microprocessor is enough to fix the problem.
Pull out the power plug of the multiswitch and satellite receiver from power grid and
then re-plug them a few seconds later.

In the case the product does not work and LED of power supply is off or blinks:

Check that the product is connected to the power grid with AC voltage. If not, connect
the product to the power grid with correct AC voltage.

Disconnect the product from the power grid and check that there is no short-circuit on
the input satellite coaxial cables, which prevents the power supplying of LNBs. If yes,
remove short-circuit and re-plug the product  into the power grid again.

The power supply can fail temporarily in case of overload or overheating. The cause can
be current consumption of devices connected to the satellite inputs of product which
exceeds the specifications, see section 2 Product Specifications. The next cause can be
the overheating of product in consequence of wrong installation, see section 4 Product
Storing and Installation. Disconnect the product from the power grid, remove the cause,
and re-plug the product  into the power grid after a few minutes again.

If the failure cannot be removed, please contact your distributor.

Power Supply Specifications

P3U27

Input Voltage

90-265 V AC, 50/60 Hz

Output Voltage

18 V DC, 12 V DC, 5 V DC

Maximum Output Current

1.0 A (18 V DC), 0.5 A (12 V DC), 0.5 A (5 V DC)

Maximum Output Power

27 W

Efficiency

75% min

Dimensions (w,d,h)

12.6 x 15.2 x 8.7 cm (power cord length 130 cm)

Temperature Range

-30 - +70 °C

3 Product Takeover

Make sure that the product is not damaged and following accessories are enclosed:

75 Ω loads for the impedance matching of unused outputs (2 pcs, others can be ordered
from EMP-Centauri, code 1000066)

In the case of damage or missing accessories please contact your dealer.

4 Product Storing and Installation

The product must not be stored and installed:

in the place with excessive humidity

in the place with excessive dust pollution, mechanical vibrations or impacts

in the place out of temperature limits specified in the section 2 Technical Specifications

close to heat sources (radiators or air ventilators, direct sunshine etc.)

in the reach of children

Do not expose the apparatus to dripping or splashing. Use the aparatus only in moderate climates
(not in tropical climate). Fix the product firmly on a wall or another hard and inflammable surface
with screws and dowels. 

The mains socket must be placed near the product. The mains plug

shall remain readily operable. The mains socket and plug must be easily available.

The product shall be in no case held only by the connected cables.

Ensure the free space for the air circulation (space on sides and bellow the product
should be at least 20 cm and the space over its top at least 50 cm).

Do not cover the product (with curtains etc.).

Do not place any containers with liquids (vases, glasses etc.) or naked flame sources
(lighted candle etc.) on the product or near the product.

5 Product Connection

Connect the product in accordance with this manual and valid regulation in you country. Use high
quality 75 Ω coaxial cable designed for satellite reception. Mount the F connectors (screw, crimp
or compress type) on the ends of coaxial cables,  in the case of using the screw F connectors
proceed according to the following picture and instructions:

1. Remove the outer coaxial cable coating in the length of approx. 15 mm.
2. Roll up the metal shielding braid and the shielding foil underneath and cut the shielding

with scissors to approx. 5 mm. 