Emotron AB 01-5016-01r0
Functional Description
31
Display the actual or last warning condition. A warning
occurs if the VSD is close to a trip condition but still in
operation. During a warning condition the red trip LED
will start to blink as long as the warning is active.
The active warning message is displayed in menu [722].
If no warning is active the message “No Error” is displayed.
You can find a list of all warnings in Table 9, page 35.
Digital Input Status [723]
Indicates the status of the digital inputs. See Fig. 29.
1
DigIn 1
2
DigIn 2
4
DigIn 4
5
DigIn 5
6
DigIn 6
7
DigIn 7
The positions one to eight (read from left to right) indicate
the status of the associated input:
1
High
0
Low
The example in Fig. 29 indicates that DigIn 1,
DigIn 3 and DigIn 6 are active at this moment.
Fig. 29 Digital input status example
Indicates the status of the digital outputs and relays. See Fig.
30.
RE indicate the status of the relays on position:
1 Relay1
2 Relay2
3 Relay3
DO indicate the status of the digital outputs on position:
1 DigOut1
2 DigOut2
The status of the associated output is shown.
1 High
0 Low
The example in Fig. 30 indicates that DigOut1 is active and
Digital Out 2
is not active.
Relay 1 is active, relay 2 and 3
are not active.
Fig. 30 Digital output status example
Analogue Input Status 1 - 2 [725]
Indicates status of the analogue inputs 1-2.
Fig. 31 Analogue input status 1-2
So the example in Fig. 31 indicates that the Analogue input1
is active.
Analogue Input Status 3-4 [726]
Indicates status of the analogue inputs 3-4. These inputs are
normally not used.
Fig. 32 Analogue input status 3-4
Analogue Output Status 1-2 [727]
Indicates status of the analogue outputs Fig. 33. E.g. if 0-20
mA output is used, the value 20% equals to 4 mA.
Fig. 33 Analogue output status 1
Stp
warn.msg
723 DigIn Status
Stp 1010
010
NOTE: The shown percentages are absolute values
based on the full range/scale of the in- our output; so
related to either 0–10 V or 0–20 mA.
NOTE: The shown percentages are absolute values
based on the full range/scale of the in- our output; so
related to either 0–10 V or 0–20 mA.
724 DigOutStatus
Stp RE 100 DO 10
2
Stp 65%
0%
4
Stp 0%
0%
2
Stp 20%
0%
Summary of Contents for EMX-D
Page 1: ......
Page 2: ...Emotron EMX D Drive system for rotary heat exchanger Instruction manual English...
Page 3: ......
Page 7: ......
Page 9: ...Emotron AB 01 5016 01r0...
Page 11: ...4 Emotron AB 01 5016 01r0...
Page 19: ...12 Installation Emotron AB 01 5016 01r0...
Page 25: ...18 Control Connections Emotron AB 01 5016 01r0...
Page 33: ...26 Operation via the Control Panel Emotron AB 01 01 5016 01r0...
Page 41: ...34 Functional Description Emotron AB 01 5016 01r0...
Page 49: ...42 Technical Data Emotron AB 01 5016 01r0...