background image

The power cable for the UPA-700 should be unplugged from the outlet during severe electrical storms, or 

when unused for a long period of time.

Only replace the fuse(s) in the UPA-700 with a fuse(s) of proper value and voltage rating. 
The UPA-700 should only be cleaned as directed in the Installation and Operation Manual. Avoid spraying 

liquids directly onto the unit and NEVER spray liquids into the vents. Care should be taken so that small 

objects do not fall into the inside of the unit.
You should seek service for your UPA-700 by qualified service personnel if any of the following occur:
1. The power-supply cord or the plug has been damaged.

 

2. Objects or liquid have fallen or spilled into the vents.

 

3. The unit has been exposed to rain.

 

4. The unit exhibits a marked change in performance.

 

5. The unit has been dropped, or its enclosure or chassis is damaged.

NOTE: TO COMPLETELY DISCONNECT THE UPA-700 FROM THE AC POWER MAINS, DISCONNECT 

THE AC POWER CORD FROM THE AC RECEPTACLE.
NOTE: THE POWER CORD ON THE UPA-700 MUST REMAIN READILY ACCESSIBLE AT ALL TIMES.

!

CAUTION

CAUTION: TO REDUCE THE RISK
OF ELECTRICAL SHOCK, DO
NOT REMOVE COVER. NO USER
SERVICEABLE PARTS INSIDE. 
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

Summary of Contents for UPA-700

Page 1: ...UPA 700 Seven Channel Power Amplifier User Manual UPA 700...

Page 2: ......

Page 3: ...ALL SERVICE TO QUALIFIED SERVICE PERSONNEL Do not install the UPA 700 near or above any heat sources such as radiators heating vents or other apparatus that produces heat Do not block any ventilation...

Page 4: ...ervice for your UPA 700 by qualified service personnel if any of the following occur 1 The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 Th...

Page 5: ...al 4 Features 5 Unpacking 6 UPA 700 Front Panel 7 UPA 700 Rear Panel 8 Quick Start 9 Connections 10 Configuration and Operation 11 Care and Maintenance 12 Specifications 13 Troubleshooting 15 Emotiva...

Page 6: ...Page 2 UPA 700...

Page 7: ...UPA 700 s quality construction and conservative ratings enable it to deliver full power even with all channels driven and our advanced engineering ensures that it will sound incredibly good even into...

Page 8: ...through the entire manual we kept things as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful suggestions If you re really in a...

Page 9: ...els driven for demanding program material and has plenty of reserves to deliver signal peaks without any sense of strain Totally stable designed for use in the real world with real speakers Shared pow...

Page 10: ...ton and remove all wrappings and shipping material It is important to save the box and all packing materials in case your power amp ever needs to be moved or shipped back to the factory for service Pl...

Page 11: ...LEDs 7 Display the status of each channel illuminate blue for normal operation or red to indicate a fault may be disabled by rear panel Status LED switch 2 Standby Button Press to switch the amplifie...

Page 12: ...ables the front panel Channel Status LEDs 3 Speaker Outputs 7 sets Full sized five way binding posts accept 4 Ohm or 8 Ohm speakers red black 4 RCA unbalanced Inputs 7 Unbalanced audio input gold plat...

Page 13: ...e location for your UPA 700 Connect your UPA 700 to a signal source Connect your UPA 700 to a pair of speakers 4 ohm or 8 ohm using reasonably heavy gauge speaker wires at least 18 gauge Find some mus...

Page 14: ...and a short 10 gauge wire for the other If you use stranded cables use care to avoid short circuits from stray strands touching Emotiva offers very high quality pre made speaker cables at reasonable p...

Page 15: ...ber Pressing this button once will switch the UPA 700 On and the LED will turn blue pressing it again will return the UPA 700 to Standby mode Trigger Mode When a trigger cable is connected to the Trig...

Page 16: ...uld be cleaned gently with a soft rag If something sticky gets on the front panel or case of the UPA 700 it should be cleaned with a mild cleaning solution applied to a soft rag followed by wiping wit...

Page 17: ...at rated power 8 Ohm load 10 Hz to 20 kHz 0 06 dB Minimum Recommended Load Impedance 4 Ohms which equals one 4 Ohm load or two paralleled 8 Ohm loads Frequency Response 10 Hz to 80 kHz 0 3 dB THD nois...

Page 18: ...te blue for normal operation or red to indicate a fault may be disabled by rear panel Status LED switch Rear Panel Controls AC Power switch rocker switch switches AC mains power Status LEDs switch sma...

Page 19: ...is heard from one or more channel s the Standby button is lit blue the Channel Status LEDs are all lit blue Reason The UPA 700 is not indicating a Fault condition Check your source Check your speaker...

Page 20: ...m if it is not made within the Term and if it is not made in strict compliance with the requirements of the How do you get service section What will Emotiva do Emotiva will at its option either i repa...

Page 21: ...CSR with a description of your problem and the serial number of the product for which the warranty claim is being made 2 The CSR will provide you with a returned material authorization number RMA 3 S...

Page 22: ...amplifier and the speakers connected to it Emotiva Audio offers high quality speaker cables and audio interconnects that feature solid engineering premium build quality excellent performance and reaso...

Page 23: ...accurate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of our produ...

Page 24: ......