6
Selecting temperature variance
Variance is a temperature difference between switching on and off. For example, if you set the
temperature of the heating system to 20 °C and the variance to 0.8 °C, the heater starts to operate,
when the room temperature drops to 19.2 °C, and is switched off when the temperature reaches
20.8 °C. Set the DIP switches (positions 1 and 2) depending on your choice of temperature variance,
as shown in the following figure.
Installation of batteries
The T15RF thermostat is powered by two 1.5V type AA batteries.
1. Insert two AA batteries into the battery compartment located inside the control unit according
to the polarities marked. Only use alkaline batteries, not rechargeable ones. When you first start
the unit, the display must show the time and room temperature.
2. If the display shows different data, gently press the reset button. To do this, use a thin, straight
object, e.g. a straightened paper clip.
3. After inserting the batteries, replace the rear cover.
4. Before you turn on the main switch of the switching unit, press the RESET button once. The
thermostat is ready for use.
Note: After inserting batteries, the transmitter needs up to about 30 minutes to stabilise parameters!
Setting the clock
1. Press the button to set the day and time. Indicator of day (no. 1-7 is flashing).
2. Use the
or
button to set the appropriate day number.
3. Press the button and use the
or
button to set the hours. Hold the
or
button
to accelerate the setting operation.
4. Press the
button and use the
or
button to set the minutes. Hold the
or
button to accelerate the setting operation.
5. Confirm the setting with the button.
If no button is pressed for a period of 10 seconds, the setting mode is automatically finished.
Setting desired temperature
1. Press the NASTAVENÍ TEPLOTY button to switch to the temperature setting mode.
2. Press the
to toggle between the economy and comfort temperature.
3. Use the
or
button to set both temperatures in steps of 0.2 °C.
4. Save the setting with the Temperature Setting button.
If no button is pressed for a period of 10 seconds, the setting mode is automatically finished.
The default comfort temperature is 21 °C for the heating system and 23 °C for air-conditioning, the
default economy temperature is 18 °C for the heating system and 26 °C for air-conditioning. Values
can be changed, as necessary.
Setting program
Selecting week/day
1. Press the “P” button, day indicator shows the day being programmed.
2. Use the
or
button to select the day you want to program. You can choose to program
the whole week, workweek weekend, or individual days.
Summary of Contents for P5611N
Page 65: ...65 1 2 230 OFF OFF self learning ID 1 2 1 5 AA 2 ID 15...
Page 66: ...66 1 2 10 3 4 5 1 4 70 6 RESET D 15 ID 1 2 3 1 2 3 1 2 3 4 5...
Page 67: ...67 T15RF NO COM L 230 AC N 230 AC 50 1 2 3 4 5 1 3 DIP 2 DIP 3 ON OFF 3...
Page 69: ...69 1 2 1 P 1 2 3 4 5 6 7 8 9 2 1 6 3 P 1 7 9 P 2 3 P...
Page 95: ...95...