3
GB | Thermostat
The P5606OT thermostat is designed for controlling heating and air-con-
ditioning systems.
Important
• Before the first use, make sure to carefully read the operating
manual for the thermostat, as well as the manual for the boiler or
air-conditioning equipment.
• Turn off power supply before installing the thermostat!
• Installation should be carried out by qualified personnel!
• During installation, observe the prescribed standards.
Technical specifications
Switched load: max. 230 V AC; 6 A for resistive load;
2 A for inductive load
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution
accuracy ±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Differential setting: 0.2 °C to 2 °C, in 0.1 °C increments
Power supply: 2× 1.5 V type AA (LR6) batteries
Back-up power supply: 1× 3 V type CR2032 battery
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 126 × 84 × 25.5 mm; 164 g
Description of Control Elements (See Fig. 1)
1 – Home (return to home screen)
2 – Next (move to the next option within the current function)
3 – Adjust value setting
4 – Confirm (confirm function selection)
5 – Copy
6 – Holiday mode
7 – Battery compartment
8 – Time and date setting
9 – Select and edit programme (PROG)
10 – Anti-freeze mode (OFF)
11 – Manual mode (MAN)
12 – Automatic mode (AUTO)
Display Description (See Fig. 2)
13 – Days
14 – Time
15 – Room temperature
16 – Heating / cooling
17 – Set temperature
Summary of Contents for P5606OT
Page 2: ...2 1 2 4 5 6 7 8 9 10 11 12 3 1 2 13 14 20 15 16 24 23 17 19 18 21 22...
Page 68: ...68 1 2 3 4 5 ON OFF NO COM NC Opentherm OT OpenTherm OT OpenTherm 2 1 5 AA 1 2...
Page 74: ...74...
Page 107: ...107 10 OFF 11 MAN 12 AUTO 2 13 14 15 16 17 18 19 20 21 22 AUTO 23 MAN 24 1 2 3 4 5...
Page 108: ...108 NO COM NC OpenTherm OT OpenTherm OT OpenTherm 2 1 5 V AA 1 2 V AUTO...
Page 110: ...110 2 PROG C 3 MO 4 TU 5 C SAVE 3 4 6 60 1 AUTO 2 3 15 MAN 1 MAN 2 1 99 1 AUTO 2 H 3 4...
Page 114: ...114...
Page 150: ...150...
Page 151: ...151...