24
Alarm Set Value High Limit Parameter
alarm set value low limit parameter value
to maximum process set value parameter.
( Default = Maximum Value of Device Scale)
Alarm set value can not be greater than this value.
This parameter value can be adjusted from
Alarm On Delay Time Parameter
It can be adjusted from 0 to 99 minutes.
( Default =0)
Alarm Off Delay Time Parameter
It can be adjusted from 0 to 99 minutes.
When this parameter is 99, if increment button is pressed,
is observed and
alarm latching output is selected. To make the alarm latching output passive,
decrement button must be pressed in main operation screen.
( Default =0)
Alarm Delay Parameter After Power On (Default =0)
This parameter defines the delay for the alarm is being active after power on.
It can be adjusted from 0 to 99 minutes.
Alarm Set Value Parameter ( Default = 10)
Alarm output is controlled according to this value.
For alarm type selection paramater
= 1 or 2, this parameter value is can be
adjusted from alarm set value low limit
parameter to alarm set value high limit
parameter, for alarm type selection paramater
= 3,4,5 or 6 this parameter
value is can be adjusted from 0 to alarm set value high limit
parameter.
Buzzer Function Selection Parameter ( Default = 1 )
Buzzer is inactive.
Buzzer is active at the end of the cooking time (Timer)
Buzzer is active, if Alarm output function selection parameter
=0 and
alarm occurs.
Buzzer is active during sensor failures.
Buzzer is active at the end of the cooking time (Timer), during alarm or
sensor failures.
Buzzer is active during this time ( Default =
)
This parameter can be observed if buzzer function selection
is
1.
It can be adjusted from 1 to 99 minutes. When this parameter is 1, if decrement
button is pressed,
is observed. Then buzzer becomes active till buzzer silence
button is pressed.
³
Button Protection Parameter ( Default = 0 )
There is no protection
Cooking time(Timer) can not be changed. Cooking ON/OFF operation is
not performed.
Process set value can not be changed.
Cooking time (Timer) and Process set value can not be changed. Cooking
ON/OFF operation is not performed.
Cooking time (Timer) and Process set value can not be changed. Cooking
ON/OFF operation is performed when
button is pressed.
Programming Mode Accessing Password
Password for entering to the programming mode is defined with this parameter.
It can be adjusted from 0 to 999. If it is 0, programming mode accessed without
entering password.
( Default = 0 )