5

Speaker output terminals are on the rear panel. The terminal under the label “COM” is COMMON. The 

terminals under the labels “4

, 70V, 100V” are Hot. The connection ways shall be COM-4

 / COM-70V / 

COM-100V. 

 

Normally the “rated power” (70V / 100V) output terminal is used in output connection. The connected 

speaker should be with a transformer, and the gross power of speakers should be less than the rated 

power of the amplifier. 

 

“Rated Impedance”(4-16

) output terminal can be used when speakers are fixed closely, and the gross 

impedance of speakers should be 4-16

 

Note:   

 

Never connect two hot terminals (labeled 4

, 70V, 100V) together. 

 

Only choose one pair of output terminals for speaker connection. The connection ways shall 

be COM-4

 / COM-70V / COM-100V.

 

 

Tone  and  volume: 

  “BASS”  and  “TREBLE”  knob  provides  the  tone  control  of  overall  system. 

MIC1,  2,  3,  4,  5  have separate  volume control.  MIC4  and  AUX1 or  MIC5  and  AUX2  have a common 

volume control knob.   

MIC

:

 MIC1 has the highest level of priority muting function and can override all input signals.   

Note: To prevent howling, keep volume level down to minimum before connecting microphone.   

 

MUTING FUNCTION 

 

    This model provides muting function. The inputs from 

MIC 2

MIC 3

MIC4

MIC5

AUX

 

1

 and 

AUX 

2

 are automatically muted by the input

 

from

 MIC

 

1, 

as the signal from 

MIC 1

 overrides other input signals. 

The level of 

MUTE

 can be adjusted within 

  the range from 

0 dB 

to

 -30 dB

 by   

adjusting 

MUTE

 control button on the   

rear panel. It is preset at

 -30 dB 

before shipping from the factory.

 

 

PRECAUTION OF INSTALLATIOM

   

1.  Do not block ventilation holes. 

2.  Do not use this amplifier if the power cord is frayed or broken. 

3.    The amplifier should not be placed in any of the areas: 

1) poor ventilation 

2) exposed to sunlight directly 

3) high ambient temperature or adjacent to heat-generating equipment; 

4) high humidity or heavy dust; 

MUTE 

dB 

 

            -30 