TB-6586
Page 3 of 3
© 2014 DESCO INDUSTRIES, INC.
Employee Owned
EMIT
- 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Website:
DescoEMIT.com
Specifications
Operating Voltage
12 VDC
Operating Temperature
32°F to 104°F (0 to 40°C)
Dimensions
8.3" x 4.0" x 3.2"
(21.1 cm x 10.2 cm x 8.1 cm)
Weight
0.9 lbs (0.4 kg)
Communication Cable
2' Long (61 cm)
Limited Warranty, Warranty Exclusions, Limit of
Liability and RMA Request Instructions
See EMIT’s Warranty -
http://emit.descoindustries.com/Warranty.aspx
COMBO TESTER X3
1. When performing a footwear test, be sure to place
both feet on the dual foot plate (one foot per plate).
When performing a wrist strap test, be sure to
completely plug in the wrist cord into the tester’s
jack.
2. Grab the ESD Glove Test Fixture’s electrode to
perform a test. Hold the electrode until the results of
the test are displayed on the Combo Tester X3.
If you are performing a wrist strap test, and the wrist
strap status LEDs do not illuminate, verify that the
wrist cord is correctly inserted into the tester.
3. The relay terminal will activate if the defined tests
are passed (if applicable).
Figure 5. Using the ESD Glove Test Fixture with the
Combo Tester X3