For ProSet™ 2100MCS & ProSet™ 2101MCS.
The MCS suction on the ProSet™ model tools is switched ON and OFF by turning the red Switch Ring (21) to
one of the three ON positions.
The MCS features an automatic timer and switch that reduces air flow to a Low-Flow mode if the tool is left idle.
Air Flow Modes
With the Switch Ring in the ON position air will flow through the MCS system. If the trigger has not been pressed
the air flow will be in the
Low-Flow
mode. Pressing the trigger will activate the
Full-Flow
mode for 15 – 20
seconds. After 15 – 20 seconds, if the trigger has not been pressed again the tool will automatically return to the
Low-Flow mode.
1. Remove Collector Bottle (22) from tool.
2. Remove Filter Cover Assembly (43).
3. Remove Filter (24). (Optional)
4. Connect tool to air supply.
5. Turn on MCS unit by rotating the Switch Ring (21) to one of the three on positions.
•
Activate Trigger (5) while rotating Switch Ring (21) to on position.
6. Using a small screwdriver rotate Low-flow adjustment screw.
•
Clockwise - reduce vacuum in low-flow mode. If screw is fully in, there won’t be vacuum during the low-
flow mode.
•
Counter clockwise – increase vacuum in low-flow mode. If screw is fully back, vacuum during the low-
flow mode will continue at full flow.
DO NOT
attempt to remove Low Flow Adjustment Screw. A flange on the blind side prevents removal
and the assembly will be damaged if removal is attempted.
7. Replace filter (24).
•
Be sure that filter does not cover both Low-flow adjustment and vacuum holes.
8. Replace Filter Cover Assembly (43).
9. Replace Collector Bottle (22).
Adjusting Low-Flow Vacuum