Heavy-duty cable BFOU(c). Different cable models may vary its wires colors.
Contact your Emerson representative for assistance when using different
cable models.
Table 4-1: Wiring scheme - single element ER probe
Junction box
(Terminal :: Pin)
Signal name
Standard cable
Multicable
Heavy-duty cable
BFOU(c)
J1 :: 1
IE+ / ERE1+
Pink
Black1
J1 :: 2
IE- / ERE1-
Brown
Brown2
J2 :: 1
RefA / ERR1+
Grey
Black2
J2 :: 2
RefB / ERR1-
Green
Blue2
J3 :: 1
E1A / ERM1+
White
Blue1
J3 :: 2
E1B / ERM1-
Yellow
Brown1
Table 4-2: Wiring scheme - LPR probe
Junction box
(Terminal :: Pin)
Signal name
Standard cable
Multicable
Heavy-duty cable
BFOU(c)
J3 :: 3
Counter / LPR-C
Pink
Black1
J3 :: 4
Ref / LPR-R
White
Blue1
J3 :: 5
Working-I / LPR-WI Yellow
Brown1
J3 :: 6
Working-V / LPR-
WV
Brown
Brown2
Not connected
None
Grey
Black2
Not connected
None
Green
Blue2
Table 4-3: Wiring scheme - Galvanic probe
Junction box
(Terminal :: Pin)
Signal name
Standard cable
Multicable
Heavy-duty cable
BFOU(c)
J2 :: 4
GALV+
Yellow
Brown1
J2 :: 5
GALV-
White
Blue1
Not connected
None
Pink
Black1
Not connected
None
Brown
Brown2
Not connected
None
Grey
Black2
Not connected
None
Green
Blue2
Quick Start Guide
April 2021
22
Emerson.com/Rosemount