Emerson Tartarini M Series Instruction Manual Download Page 10

Type M

10

ParTS LIST

key Description

  1 

Adjusting Screw

  2 

upper spring holder

 3 

Tube

 4 

Label

  5*  O-ring

 6 

Spacer

  7*  O-ring

 8 

Plate

  9*  Shaped Diaphragm

  10  Diaphragm tube

 11  Plate

 12  Plate

  13  Vibrations dumper

 14  Screw

  15*  O-ring

  16*  O-ring

 17  Plate

 18  Plug

  19  Special nut

  20*  O-ring

  21*  Diaphragm

 22  Screw

 23  Washer

 24  Nut

  25  Lower cover

 26  Spring

  27*  O-ring

 28  Cap

 29  Screw

 30  Body

  31  Pad holder

 32  Stem

  33  Pad retainer

  34*  Pad unit

 35  Seat

  36*  O-ring

  37*  Antifriction ring

  38  Pad holder

  39*  Pad

 40  Spring

  41*  O-ring

  42  Slam-shut spring holder

  43  Slam-shut shutter

  44  Cup unit

 45  Connection

  46  Elastic ring

  47*  Gasket

 48  Eyebolt

  49*  O-ring

 50  Plug

 51  Screw

  52  Diaphragm hub

 53  Diaphragm

 54  Pawl

 55  Spring

 56  Bush

  57  Travel indicator

 58  Label

 59  Label

 60  Sheath

  61  upper cover unit

  62  Spring holder plate

  63  Spring holder plate

 64  Washer

  65  Autolocking nut

 66  Spring

 67  Connection

  68*  O-ring

  69  Impulse pipe connection

 70  Extension

  71  Impulse pipe

 72  Connection

 75  Cam

  76*  Antifriction ring

 77  Bush

  78  Elastic pin

  79*  O-ring

  80*  Antifriction ring

  81*  O-ring

 82  Plug

  83*  O-ring

  84  Elastic ring

 85  Shaft

 86  Label

 87  Rivet

 88  Hub

 89  Screw

  90*  O-ring

 91  Shaft

  92*  O-ring

 93  Screw

 94  Spring

  95*  Gasket

 96  Plug

 97  Ball 

 98  Screw

 99  Ball

100 Screw

101*  O-ring

102 Stem

103 Spring

104 Plug

105  Slam-shut spring holder

106*  O-ring

107 Screw

108 Plug

109 Plug

110 Connection

113  Special washer

117*  O-ring

118*  O-ring

119 Plug

120*  O-ring

121  Guide bush

122 Piston

123*  O-ring

124 Plate

125 Connection

126  Monitor cap

127  Monitor plate

128*  O-ring

129  Monitor cup

130  Monitor stem

132 Disco

133  SR silencer

134  OS/66 Slam-shut controller

135 Washer

150  Reset lever unit

Rubber parts marked with (*) are supplied in 

the “spare parts kit”, recommended as stock.

To order the kit it is necessary to 

communicate to us the type of the regulator 

and its serial number.

TrOuBLEShOOTING

Table 5.

  M Series General Troubleshooting

SymPTOmS

CauSE

aCTIONS

The regulator does not open

Lack of incoming gas

Check the station feeding

The slam-shut controller has not been reset

Manually reset the slam-shut controller

Drop in pressure downstream from the regulator

Insufficient upstream pressure

Check the station feeding

Flow requirements higher than the flow

that the regulator can supply

Check the regulator sizing

Filter upstream is obstructed

Clean or replace the filter

Broken spring

Replace the spring

Increase in pressure downstream from the regulator or 

safety devices being activated 

(slam-shut valve)

Tight shutoff gaskets are worn

Replace gaskets

Deposits of grime on the tight shutoff pad are

obstructing proper positioning of the shutter

Clean or replace the pad

Diaphragm damaged

Replace the diaphragm

Slam-shut device does not execute tight  

shutoff procedure

O-ring and/or slam-shut pad worn

Replace the O-ring or/and the slam-shut pad

Slam-shut seat damaged

Replace the slam-shut seat

Summary of Contents for Tartarini M Series

Page 1: ...ng of burners Figure 1 Regulator Type MBN This product has been designed to be used with fuel gases of 1st and 2nd family according to EN 437 and with other non aggressive and non fuel gases For any other gases other than natural gas please contact your local sales agent The following versions are available MN MF Regulator pressure accessories MBN MBF Regulator with slam shut safety accessories MB...

Page 2: ...I 150 Warning The pressure temperature limits indicated in this instruction manual or any applicable stan dard or code limitation should not be exceeded Maximum Operating Inlet Pressure MN MBN MBN M DN 25 40 50 10 bar MN MBN MBN M DN 65 80 100 5 bar MF MBF MBF M DN 25 40 50 10 bar MF MBF MBF M DN 80 100 5 bar MN PST MBN PST MBN M PST 19 6 bar MF PST MBF PST MBF M PST 19 6 bar MN AP MBN AP MBN M AP...

Page 3: ...al external and internal explosive atmosphere can be present in equipment gas pressure regulating measuring stations installations If a presence of foreign material in the pipelines is foreseen and purge by inert gas is not carried out the following procedure is recommended to avoid any possible external ignition source inside the equipment due to mechanical generated sparks drainage to safe area ...

Page 4: ...0 55 59 64 80 298 500 650 145 215 73 77 83 620 100 352 500 500 660 180 265 110 115 125 620 Table 4 Dimensions mm and Weights kg MF MBF and MBF M Regulators MN MBN MBN M DN I A H H1 H2 MONITOR VERSION WEIGHT STD AP APA MN MBN MBN M 25x65 184 380 500 95 140 31 33 37 40x80 222 500 380 580 100 160 53 55 59 50x100 254 600 120 170 59 62 67 65x100 276 620 132 200 62 66 72 80x150 298 500 650 145 215 80 84...

Page 5: ...reached at outlet The opposite occurs whenever outlet pressure increases Precision perfect balancing of control member is assured under all operating conditions by the inlet pressure which operates in the counterbalancing chamber How the Monitor Works The monitor or emergency regulator is used as a safety device in gas pressure reduction systems The purpose of this device is to protect the system ...

Page 6: ... x DN 4 x DN SS Pipe ø 6 mm Monitor Regulator SS Pipe ø 15 mm SS Pipe ø 10 mm REGULATOR TYPE MBN DN 25 TO DN 65 WITH INTERNAL IMPULSE CONNECTION REGULATOR TYPE MBN DN 80 TO DN 100 WITH EXTERNAL IMPULSE CONNECTION MONITOR TYPE MBF M AND REGULATOR TYPE MN WITH EXTERNAL IMPULSE CONNECTIONS Figure 6 Connection Schematics Installation ...

Page 7: ... In accordance with clause 7 3 7 2 of aforesaid standards the gas shall be cleaned by proper filters separators scrubbers to avoid any technical and reasonable hazard of erosion or abrasion for pressure containing parts All pressure equipment should be installed in a non seismic area and should not undergo fire and thunderbolt action All pipelines should be cleaned before installation of the regul...

Page 8: ...ble National or Industry codes standards and regulations recommendations In accordance with applicable National or Industry codes standards and regulations recommendations all hazards covered by specific tests after final assembling before applying the CE marking shall be covered also after every subsequent reassembly at installation site in order to ensure that the equipment will be safe througho...

Page 9: ...late key 12 and the diaphragm tube key 10 g Dismount the assembly composed by the stem key 32 and the shaped diaphragm key 9 unscrew the spacer key 6 and disassemble the various parts check the shaped diaphragm key 9 and the O ring key 5 and 7 Only for the AP APA and PST version slide out the piston key 122 and the stem key 32 check the O ring key 123 and the guide bush key 121 h Unscrew the screw...

Page 10: ... Plug 110 Connection 113 Special washer 117 O ring 118 O ring 119 Plug 120 O ring 121 Guide bush 122 Piston 123 O ring 124 Plate 125 Connection 126 Monitor cap 127 Monitor plate 128 O ring 129 Monitor cup 130 Monitor stem 132 Disco 133 SR silencer 134 OS 66 Slam shut controller 135 Washer 150 Reset lever unit Rubber parts marked with are supplied in the spare parts kit recommended as stock To orde...

Page 11: ...4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 75 76 78 81 83 82 80 84 85 86 87 93 80 88 79 76 77 89 27 28 37 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 66 65 64 63 62 61 60 59 58 57 56 55 54 47 22 29 48 49 50 51 52 53 134 150 135 7 39 117 41 43 38 113 Schematic Assemblies ...

Page 12: ...Type M 12 T T E I S R A M I R O N G E R W C B C C G 100 92 90 91 72 71 68 69 70 69 68 67 20 19 101 18 19 20 106 105 104 103 102 97 99 94 95 96 98 Figure 7 M Series Regulator Assembly continued LM 1392 ...

Page 13: ...121 122 123 120 14 44 15 8 5 7 108 68 109 DN 25 TO DN 100 AP APA AND PST VERSION MN MBN DN 80 TO DN 100 MBN M DETAIL 49 50 110 EXTERNAL IMPULSE LINE DETAIL 113 MN MF DN 25 DETAIL 119 118 107 MN MF DN 40 TO DN 100 DETAIL 7 44 To downstream stainless steel pipe Ø 15 mm ...

Page 14: ... 111 124 124 111 112 124 111 112 21 21 111 112 DN 25 DETAIL DN 100 DETAIL DN 100 AP VERSION DN 100 PST VERSION DN 25 TO DN 80 APA VERSION DN 100 APA VERSION Figure 7 M Series Regulator Assembly continued LM 1392 ...

Page 15: ...4 8 37 7 AP AND APA MONITOR VERSION SR SILENCED VERSION DETAIL DN 25 MONITOR VERSION DN 40 TO DN 100 MONITOR VERSION 113 B B B To downstream stainless steel pipe Ø 10 mm To downstream stainless steel pipe Ø 10 mm To downstream stainless steel pipe Ø 10 mm Figure 7 M Series Regulator Assembly continued LM 1392 ...

Page 16: ...ers McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Africa Dubai United Arab Emirates Tel 971 4811 8100 For further information visit www emersonprocess com regulators Natural Gas Technologies Emerson Process Management Regulator Technologies Inc USA Headquar...

Reviews: