background image

3

Type FL

taking out of service (shutdown)

!

WArNING

to avoid personal injury resulting from sudden 

release of pressure, isolate the regulator from all 

pressure before attempting disassembly.

Parts List

type FL Main Valve (Figure 1)

Key Description 

Inlet Flange 

2* 

Anti-Friction Ring, (6 required)

3* 

O-ring (3 required)

4* 

Body O-ring

 

  DN 25, 50, 80 and 100 / NPS 1, 2, 3 and 4 (2 required) 

 

  DN 150 and 200 / NPS 6 and 8 

Socket Head Screw

 

  DN 25, 50, 80, 100 and 150 / NPS 1, 2, 3, 4 and 6

 

    (16 required)

 

  DN 200 and 250 / NPS 8 and 10 (24 required) 

Spring

Tube Fitting 

 

Inlet Plate

Flange Bolt

 

  DN 25, 50, 80 and 100 / NPS 1, 2, 3 and 4 (16 required)

 

  DN 150 / NPS 6 (24 required) 

 

  DN 200 / NPS 8 (30 required) 

 

  DN 250 / NPS 10 (36 required) 

10*  Diaphragm
11 

Inlet Body Cover, not available for DN 250 / NPS 10

12 

Outlet Plate

13 

Outlet Body Cover

14 

Washer

 

  DN 25, 50, 80 and 100 / NPS 1, 2, 3 and 4 (16 required) 

 

  DN 150 / NPS 6 (24 required) 

 

  DN 200 / NPS 8 (30 required) 

 

  DN 250 / NPS 10 (36 required)

15 

Nut

 

  DN 25, 50, 80 and 100 / NPS 1, 2, 3 and 4 (16 required) 

 

  DN 150 / NPS 6 (24 required) 

 

  DN 200 / NPS 8 (30 required) 

 

  DN 250 / NPS 10 (36 required) 

16 

Sleeve

17 

Tube Fitting 

18*  O-ring
19 

Disk Holder

 

  Type FL

 

  Type FL-SR, FL-SRII, FL-SR/SRS or FL-SRII/SRS

(1)

20*  Disk
21 

Disk Retainer

22 

Outlet Flange

23 

Gasket

24 

Spacer

(2)

25 

Socket Head Screw

26*  O-ring

27 

Socket Head Screw

 

  DN 25 and 50 / NPS 1 and 2 (6 required) 

 

  DN 80 and 100 / NPS 3 and 4 (12 required) 

 

  DN 150 / NPS 6 (8 required) 

 

  DN 200 / NPS 8 (16 required) 

 

  DN 250 / NPS 10 (20 required) 

28*  O-ring
29 

Nameplate 

30 

Nameplate Sticker 

 

31 

Drive Screw (4 required)

32 

Flow Arrow 

33 

Spring Collet, not available for DN 250 / NPS 10

34 

Indicator Stem, not available for DN 250 / NPS 10

35*  O-ring
36 

Indicator Fitting

37A*  O-ring
37B*  O-ring
38 

Indicator Bushing

39 

Indicator Scale 

40 

Indicator Cover, not available for DN 250 / NPS 10

43 

Type SR Silencer

46*  O-ring
47*  O-ring
48 

Washer, not available for DN 250 / NPS 10

59 

Eyebolt 

 

  DN 150 / NPS 6 (2 required) 

 

  DN 200 / NPS 8 (2 required) 

 

  DN 250 / NPS 10 (2 required) 

61 

Pin (DN 150 / NPS 6 only) (8 required) 

62 

Screw 

 

  DN 200 and 250 / NPS 8 and 10 only (6 required) 

 

63 

Washer 

 

  DN 200 and 250 / NPS 8 and 10 only (6 required) 

64 

Socket Head Screw

 

  DN 150 / NPS 6 (16 required) 

 

  DN 200 / NPS 8 (20 required) 

65 

Spring Pin 

 

  DN 200 and 250 / NPS 8 and 10 only 

66*  Back-up Rings (2 required) 
67 

Disk Support (2 required)

type srs Main Valve (Figure 3)

Key Description

 

200  Body
201  Retainer
202  Stud, not available for DN 200 / NPS 8 body
202  Nut, for DN 200 / NPS 8 body only
203  Attenuator Plate, not available for DN 200 / NPS 8 body
204  Spring Pin
 

  DN 25, 50 and 80 / NPS 1, 2 and 3 (2 required) 

 

  DN 100 and 150 / NPS 4 and 6 

 

205  Ring
206  Nut (3 required), not available for DN 200 / NPS 8 body
206  Spacer, for DN 200 / NPS 8 body only
207  Attenuator Plate
208  Attenuator Plate

*Recommended Spare Part

 

1.  DN 200 and 250 / NPS 8 and 10 are available only with Types SRII and SRII/SRS silencers.

2.  For DN 200 / NPS 8 Type FL with Type SRS, the spacer will be installed upstream and not downstream. Please see DN 200 / NPS 8 for Part Number.

Key Description 

Summary of Contents for TARTARINI FL Series

Page 1: ...ential Pressure continued 2 Full Open DN 25 to 100 NPS 1 to 4 1 00 bar d 14 5 psid DN 150 and 200 NPS 6 and 8 0 50 bar d 7 3 psid DN 250 NPS 10 0 6 bar d 8 7 psid Outlet Pressure Ranges See Table 1 Pressure Registration External Temperature Capabilities 1 3 Nitrile NBR Fluorocarbon FKM or Polyurethane PU Disk 20 to 60 C 4 to 140 F Nitrile NBR or Polyurethane PU Disk 29 to 60 C 20 to 140 F 5 Approx...

Page 2: ...regulator out of service immediately may create a hazardous condition Personal injury equipment damage or leakage due to escaping fluid or bursting of pressure containing parts may result if this regulator is overpressured or is installed where service conditions could exceed the limits given in the Specifications section or where conditions exceed any ratings of the adjacent piping or piping conn...

Page 3: ...required DN 200 NPS 8 16 required DN 250 NPS 10 20 required 28 O ring 29 Nameplate 30 Nameplate Sticker 31 Drive Screw 4 required 32 Flow Arrow 33 Spring Collet not available for DN 250 NPS 10 34 Indicator Stem not available for DN 250 NPS 10 35 O ring 36 Indicator Fitting 37A O ring 37B O ring 38 Indicator Bushing 39 Indicator Scale 40 Indicator Cover not available for DN 250 NPS 10 43 Type SR Si...

Page 4: ... Cover O ring 19 Orifice 20 Nut 21 Lower Cover 22 Pad Holder 23 Stem 24 Nameplate 25 Stem O ring 26 Upper Diaphragm Nut 27 Damper Adjusting Screw with Hole 28 Restrictor Damper O ring 29 Damper Restrictor Plate Types PRX 120 and PRX 120 AP Types PRX 125 and PRX 125 AP 30 Ring Nut 31 Nameplate Screw 32 Restrictor Adjusting Screw with Hole 33 Plug Types PRX 125 and PRX 125 AP only 34 Plug Types PRX ...

Page 5: ...5 Type FL DN 200 NPS 8 Figure 1 Type FL Main Valve Assembly LM 1403 40 34 38 36 66 37B 35 33 31 32 31 30 29 28 65 27 26 1 2 3 2 2 3 2 6 4 2 3 5 2 8 9 10 11 12 13 14 15 16 18 59 22 23 24 59 64 ...

Page 6: ...21 20 21 48 Figure 2 Polyurethane PU Main Valve Assembly DN 25 AND 50 NPS 1 AND 2 without silencer DN 80 TO 150 NPS 3 TO 6 without silencer DN 200 TO 250 NPS 8 TO 10 without silencer DN 80 TO 150 NPS 3 TO 6 with Type sr DN 25 AND 50 NPS 1 AND 2 with Type sr ersa03388 ersa03389 ersa03393 ersa03394 ersa03396 ...

Page 7: ...Figure 3 Type SRS Assembly 211 210 206 209 208 206 207 206 200 201 202 203 204 205 23 24 200 spacer details for DN 150 TO 300 NPS 6 TO 12 DN 25 TO 150 NPS 1 TO 6 spacer details for sizes smaller than DN 150 NPS 6 ...

Page 8: ...8 Type FL 57 54 53 55 L PORT DN 25 TO 50 NPS 1 TO 2 A PORT TYPE PRX 120 B PORT TYPE SA 2 50 56 52 GE46220_A Figure 4 Type FL Single Pilot Mounting Assembly ...

Page 9: ... A 18 11 26 28 34 29 31 28 34 33 33 28 31 29 28 34 34 18 22 19 14 17 16 18 14 13 13 15 25 S S L L B B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 14 18 19 13 11 20 10 11 21 22 23 24 18 11 26 25 Figure 5 PRX Series Pilot Assembly Type PRX 131 or PRX 131 AP assembly Section a a Type PRX 120 or PRX 125 ...

Page 10: ...egulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Africa Dubai United Arab Emirates Tel 971 4811 8100 Natural Gas Technologies Emerson Process Management Regulator Technologies Inc...